Sensitivity and specificity of auditory steady‐state response testing

نویسندگان

  • Camila Maia Rabelo
  • Eliane Schochat
چکیده

INTRODUCTION The ASSR test is an electrophysiological test that evaluates, among other aspects, neural synchrony, based on the frequency or amplitude modulation of tones. OBJECTIVE The aim of this study was to determine the sensitivity and specificity of auditory steady-state response testing in detecting lesions and dysfunctions of the central auditory nervous system. METHODS Seventy volunteers were divided into three groups: those with normal hearing; those with mesial temporal sclerosis; and those with central auditory processing disorder. All subjects underwent auditory steady-state response testing of both ears at 500 Hz and 2000 Hz (frequency modulation, 46 Hz). The difference between auditory steady-state response-estimated thresholds and behavioral thresholds (audiometric evaluation) was calculated. RESULTS Estimated thresholds were significantly higher in the mesial temporal sclerosis group than in the normal and central auditory processing disorder groups. In addition, the difference between auditory steady-state response-estimated and behavioral thresholds was greatest in the mesial temporal sclerosis group when compared to the normal group than in the central auditory processing disorder group compared to the normal group. DISCUSSION Research focusing on central auditory nervous system (CANS) lesions has shown that individuals with CANS lesions present a greater difference between ASSR-estimated thresholds and actual behavioral thresholds; ASSR-estimated thresholds being significantly worse than behavioral thresholds in subjects with CANS insults. This is most likely because the disorder prevents the transmission of the sound stimulus from being in phase with the received stimulus, resulting in asynchronous transmitter release. Another possible cause of the greater difference between the ASSR-estimated thresholds and the behavioral thresholds is impaired temporal resolution. CONCLUSIONS The overall sensitivity of auditory steady-state response testing was lower than its overall specificity. Although the overall specificity was high, it was lower in the central auditory processing disorder group than in the mesial temporal sclerosis group. Overall sensitivity was also lower in the central auditory processing disorder group than in the mesial temporal sclerosis group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Mild Cognitive Impairment and Alzheimer Disease on Auditory Steady-State Responses

Introduction: Mild Cognitive Impairment (MCI), a disorder of the elderly people, is difficult to diagnose and often progresses to Alzheimer Disease (AD). Temporal region is one of the initial areas, which gets impaired in the early stage of AD. Therefore, auditory cortical evoked potential could be a valuable neuromarker for detecting MCI and AD.  Methods: In this study, the thresholds of...

متن کامل

Auditory sensitivity in children using the auditory steady-state response.

OBJECTIVE To determine the effectiveness of auditory steady-state response (ASSR) as a measure of hearing sensitivity in young children suspect for significant hearing loss. DESIGN Within-subject comparisons of click auditory brainstem response (ABR) thresholds and ASSR thresholds. SUBJECTS The study population comprised 42 children suspect for hearing loss and subsequently referred for hea...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Assessment of the Prevalence of Hearing Impairment in Neonates Born in Imam Reza, Ghaem and OM-Albanin Hospitals of Mashhad

Introduction: The prevalence of hearing loss in neonates is 2-5 out of every 1,000 live births. Global Health Committee, American Academy of Otolaryngology, and American Academy of Pediatrics have recommended that hearing loss in infants be identified, and treated when possible, prior to 6 months of age. This study was designed with the aim to screen the hearing of neonates in Mashhad, Iran. Me...

متن کامل

Validation of multi-channel auditory steady-state response in adults with sensorineural hearing loss.

OBJECTIVE For various medico-legal and financial reasons, some patients may clinically demonstrate an exaggerated hearing loss that varies in degree, nature and laterality. The purpose of this study was to evaluate whether multi-channel auditory steady-state response measurement can be used as an objective test of auditory thresholds in adults with sensorineural hearing loss. STUDY DESIGN AND...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 66  شماره 

صفحات  -

تاریخ انتشار 2011