Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI.
نویسندگان
چکیده
We introduce a novel method of prospectively compensating for subject motion in neuroanatomical imaging. Short three-dimensional echo-planar imaging volumetric navigators are embedded in a long three-dimensional sequence, and the resulting image volumes are registered to provide an estimate of the subject's location in the scanner at a cost of less than 500 ms, ~ 1% change in contrast, and ~3% change in intensity. This time fits well into the existing gaps in sequences routinely used for neuroimaging, thus giving a motion-corrected sequence with no extra time required. We also demonstrate motion-driven selective reacquisition of k-space to further compensate for subject motion. We perform multiple validation experiments to evaluate accuracy, navigator impact on tissue intensity/contrast, and the improvement in final output. The complete system operates without adding additional hardware to the scanner and requires no external calibration, making it suitable for high-throughput environments.
منابع مشابه
Diffusion imaging with prospective motion correction and reacquisition.
A major source of artifacts in diffusion-weighted imaging is subject motion. Slow bulk subject motion causes misalignment of data when more than one average or diffusion gradient direction is acquired. Fast bulk subject motion can cause signal dropout artifacts in diffusion-weighted images and results in erroneous derived maps, e.g., fractional anisotropy maps. To address both types of artifact...
متن کاملProspective head motion correction in 3D FLASH using EPI-based volumetric navigators (vNavs)
Prospective head motion correction in 3D FLASH using EPI-based volumetric navigators (vNavs) M. Dylan Tisdall, Himanshu Bhat, Keith Heberlein, and André J. W. van der Kouwe A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, United States, Radiology, Harvard Medical School, Boston, Massachusetts, United States, Siemens Medical Solutions USA ...
متن کاملProspective motion correction with FID-triggered image navigators
shaking; (b) Changes in volumetric measurements and image quality due to motion correction). The p-value is shown as calculated with the Wilcoxon rank-sum test when comparing the volumes with and without correction. 1417 Prospective motion correction with FID-triggered image navigators Maryna Babayeva, Pavel Falkovskiy, Tom Hilbert, Guillaume Bonnier, Bénédicte Maréchal, Reto Meuli, Jean-Philip...
متن کاملImplementation of Anatomical Navigators for Real Time Motion Correction in Diffusion Tensor Imaging
Thesis: Implementation of Anatomical Navigators for Real Time Motion Correction in Diffusion Tensor Imaging Author‟s Name: Alkathafi A. Alhamud Date: 10-02-2012 Diffusion Tensor Imaging (DTI) is used to detect microstructural changes in the human brain. Although echo planar imaging (EPI) has been implemented in diffusion pulse sequences to minimize the effect of subject motion, motion artifacts...
متن کاملDiffusion tensor MRI of the human heart In Vivo with a navigator based free breathing approach
Background Diffusion tensor MRI (DTI) provides a non-invasive approach for the depiction of the myocardial fibre architecture [1-5]. In vivo DTI remains extremely challenging due to the need for motion correction. Several techniques have been used to compensate for respiratory motion: multiple breath-holds (>36 per patient), synchronised breathing and retrospective navigators based on image cro...