Agreement on the accuracy of thallium stress testing.

نویسنده

  • K L Gould
چکیده

I. The average reported sensitivity and specificity of thallium exercise testing in 2,877 cumulative cases published since 1983 (2-7), weighted for the number of cases in each study, is 83% and 53%, respectively, associated with approximately 17% false negative and 47% false positive results (Table I). 2. Referral bias cannot completely explain this poor diagnostic accuracy, which is therefore a real limitation, reducing clinical utility of thallium stress testing as currently used. 3. This degree of error in a noninvasive diagnostic test incurs considerable economic and personal costs related to making the correct diagnosis by coronary arteriography, as reported in studies (14-16) published since that editorial comment (1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THALLIUM-201 STRESS TEST IN 156 PATIENTS WITH SUSPECTED CORONARY ARTERY DISEASE

Currently, myocardial TI-201 scintigraphy is most often performed in conjunction with exercise stress testing in patients with suspected or known CAD. Stress thallium tests were performed for 156 patients with and without old myocardial infarctions complaining of chest pain. All of them underwent contrast coronary angiography. Perfusion defects were mostly manifested as reversible defects ...

متن کامل

Accuracy of cardiokymography during exercise testing: results of a multicenter study.

To determine the diagnostic accuracy of cardiokymography, recorded 2 to 3 minutes after exercise, 617 patients undergoing cardiac catheterization were evaluated from 12 participating centers using a standardized protocol. Adequate cardiokymographic tracings, which were obtained in 82% of patients, were dependent on the skill of the operator and on certain patient characteristics. Of the 327 pat...

متن کامل

Effect of exercise position during stress testing on cardiac and pulmonary thallium kinetics and accuracy in evaluating coronary artery disease.

We compared the effects of symptom-limited upright and supine exercise on 201Tl distribution and kinetics in the heart and lungs of 100 consecutive patients. Our analysis was based on data obtained with a digital gamma camera in the 45 degrees left anterior oblique position at 5, 40, 240, and 275 min postadministration of [201Tl]chloride. We found significant differences in the results at the 5...

متن کامل

Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop Combined with Flame Atomic Absorption Spectrometry for Preconcentration and Determination of Thallium(III) in Water Samples

Dispersive Liquid-Liquid MicroExtraction technique based on Solidification of a Floating Organic drop (DLLME-SFO) combined with flame atomic absorption spectrometry was developed for determination of thallium in water sample. An appropriate mixture of acetone and 1-undecanol was rapidly injected into an aqueous sample containing TlCl4- which forms an ion pair with bril...

متن کامل

Cost-effectiveness of alternative test strategies for the diagnosis of coronary artery disease.

BACKGROUND The appropriate roles for several diagnostic tests for coronary disease are uncertain. OBJECTIVE To evaluate the cost-effectiveness of alternative approaches to diagnosis of coronary disease. DESIGN Meta-analysis of the accuracy of alternative diagnostic tests plus decision analysis to assess the health outcomes and costs of alternative diagnostic strategies for patients at inter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 1990