STIR MR imaging of the orbit.
نویسندگان
چکیده
Fifteen patients with CT-documented orbital lesions were evaluated with MR imaging at 1.5 T with both conventional spin-echo (SE) and short inversion time inversion recovery (STIR) sequences. Fat signal was reliably nulled at inversion times of approximately 120-200 msec in all cases, thereby allowing clear detection of all retrobulbar lesions and normal structures on STIR images as markedly hyperintense relative to fat. All lesions were also clearly depicted on SE images; in fact, short repetition time/short echo time SE sequences were at least as useful as STIR images for illustrating anatomic structures and mass lesions, and in a much shorter scanning time. Separation of optic nerve from perioptic subarachnoid space was clear on SE images, but often difficult or impossible on STIR images owing to the relatively high intensity of normal optic nerves on STIR images. The synergism of relaxation prolongation with STIR actually resulted in loss of information, as any ability to separate the effects of T1 from T2 on signal intensity was impossible when STIR was the sole pulse sequence. We believe that more information is obtained with standard SE sequences than with STIR sequences, and therefore SE remains the method of choice for orbital MR imaging.
منابع مشابه
Detecting breast cancer with non-contrast MR imaging: combining diffusion-weighted and STIR imaging.
We combined diffusion-weighted (DWI) and short TI inversion recovery (STIR) imaging to evaluate the diagnostic capability of non-contrast magnetic resonance (MR) imaging to detect breast cancer. Seventy women patients underwent mammography and MR imaging with combined DWI (b factor: 1000) and STIR that revealed malignancy, and postoperative pathological examination confirmed breast cancer. Inte...
متن کاملGadolinium-DTPA-enhanced MR imaging of spinal neoplasms: preliminary investigation and comparison with unenhanced spin-echo and STIR sequences.
Unenhanced T1- and T2-weighted spin-echo, short inversion time inversion recovery (STIR), and gadolinium-DTPA (Gd-DTPA)-enhanced spin-echo and STIR imaging techniques were used in 20 patients as part of a multicenter study to assess the safety and efficacy of Gd-DTPA in spinal imaging. Five patients had normal MR scans. Of those with lesions, both Gd-DTPA-enhanced T1-weighted spin-echo and unen...
متن کاملDiffusion-Weighted Imaging of the Lung Cancers: Preliminary Evaluation of Capability for Detection and Subtype Classification in Pulmonary Adenocarcinomas on Comparison with STIR Turbo SE Imaging
Introduction: Recently, image quality and diagnostic capability of chest MR imaging have been improving according to the advancement of MR system and sequence and the utilization of contrast media, and potential advantages of chest MR imaging have also been addressed in many literatures (1,2). In addition, it has been suggested that diffusion-weighted imaging (DWI) could be useful for assessmen...
متن کاملComparison of three MR sequences for the detection of cervical cord lesions in patients with multiple sclerosis.
BACKGROUND AND PURPOSE Improving the sensitivity of MR imaging for the detection of multiple sclerosis (MS) lesions in the cord might be useful in the diagnostic workup and could lead to a better understanding of the evolution of the disease. The purpose of this study was to compare fast spin-echo (FSE) with magnetization transfer-prepared gradient-echo (MT-GE) and fast short-inversion-time inv...
متن کاملDifferential diagnosis of vertebral compression fracture using in-phase/opposed-phase and short TI inversion recovery imaging.
BACKGROUND Magnetic resonance imaging (MRI) is highly useful for detecting diseases of the bone marrow. The sensitivity for detecting compression fracture is very high, but specificity is low for differential diagnosis between malignant and benign cases. PURPOSE To evaluate the usefulness of in-phase/opposed-phase and short TI inversion recovery (STIR) magnetic resonance imaging (MRI) of bone...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 151 5 شماره
صفحات -
تاریخ انتشار 1988