Arterial line filters ranked for gaseous micro-emboli separation performance: an in vitro study.

نویسنده

  • Jeffrey B Riley
چکیده

UNLABELLED Arterial line filters (ALFs) are arguably the most important component in the cardiopulmonary bypass circuit to protect the patient from gaseous macro- and micro-emboli (GME) originating in the perfusion circuit. The GME separating ability of 10 ALFs was ranked according to seven performance criteria. Ten ALFs rated between 20 and 43 microm were evaluated for flow resistance, the count, size, and volume of GME passed after a 10-mL room air bolus, and the ability to separate a high-count, 10- to 200-microm flowing distribution of GME. The Luna Innovations EDAC emboli detector was used to size, count, and sort GME. Three test trials were conducted for 3 each of the 10 filters. Performance criteria were correlated by regression analysis, statistically compared using analysis of variance, or ranked using non-parametric tests. Significance was set at 0.05. Weighting all seven test parameters equally, the most effective ALFs were the Cobe 21 and Gish 25-microm filters. The Pall LG-6 ranked more efficient than the Medtronic 20 and Dideco 27-microm filters. The Cobe 43, Terumo 40, Medtronic 38, Terumo 37, and Gish 40-microm filters were less effective as a group compared with the other filters. For the 10 filters, blood flow resistance was not correlated to rated pore size. Generally, the smaller the pore rating, the higher the GME separation ability rank, except for the leuko-reduction filter, which performed more effectively than other large pore filters. KEYWORDS arterial line filter, gaseous microemboli, in vitro test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gaseous micro emboli: concepts and considerations.

The production of gaseous micro emboli associated with bubble oxygenators during extracorporeal perfusion has prompted considerable attention regarding product design and arterial filtration needs. There are a variety of routes by which gas bubbles are introduced into the vasculature. As invasive diagnostics and extracorporeal perfusion are used more widely, likewise, the incidence of gas embol...

متن کامل

An in vitro study of the effectiveness of carbon dioxide flushing of arterial line filters.

Gaseous microemboli (GMEs) have been connected to neurologic impairment and other ischemic complications after surgery. The components of the extracorporeal circuit (ECC) have a large influence on GME production. This in vitro study investigates the use of carbon dioxide flushing of the 38-microm Medtronic Affinity CB351 and 38-microm Medtronic Affinity 351 arterial line filters (ALFs) to decre...

متن کامل

Blood temperature management and gaseous microemboli creation: an in-vitro analysis.

Gaseous microemboli have been associated with post operative neurological deficits in patients undergoing cardiopulmonary bypass. Creating an optimal perfusion system that minimizes microemboli production and has enhanced abilities to sequester entrained air during the bypass procedure has been an important focus. This study examines the air-handling capabilities of a cardiopulmonary bypass cir...

متن کامل

In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.

The delivery of gaseous microemboli (GME) by the cardiopulmonary bypass circuit should be minimized whenever possible. Innovations in components, such as the integration of arterial line filter (ALF) and ALFs with reduced priming volumes, have provided clinicians with circuit design options. However, before adopting these components clinically, their GME handling ability should be assessed. Thi...

متن کامل

Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation.

The detection and prevention of gaseous microemboli (GMEs) during cardiopulmonary bypass has generated considerable interest within the cardiac surgical community. There have been several landmark papers that have used transcranial Doppler devices during cardiopulmonary bypass to detect gaseous microemboli activity in the patients' middle cerebral artery during perfusionist interventions. To de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2008