Adsorptive Stripping Anodic Voltammetric Determination of Thioctic Acid in Bulk and Pharmaceutical Formulations
نویسنده
چکیده
The electrochemical behavior of thioctic acid at the hanging mercury drop electrode was studied in different supporting electrolytes. In Britton - Robinson buffer pH 3.29, the square - wave adsorptive anodic stripping voltammogram of thioctic acid exhibited a single well - defined anodic peak at about -0.21 V vs Ag/AgCl. The peak response was characterized with respect to pH, preconcentration time, accumulation potential, supporting electrolytes, frequency, scan increment and pulse amplitude. Under the optimized conditions, a fully validated, simple, high sensitive, precise and inexpensive square - wave adsorptive anodic stripping voltammetric procedure was described for determination of thioctic acid in bulk form and tablets. The obtained results were in good agreement with those obtained with the reference method. The calibration graph was linear over the range 5 × 10(-8) - 9 × 10(-7) M (r=0.9997) with accumulation for 60 s at -0.4 V vs Ag/AgCl and the detection limit was ca. 1.2 × 10(-8) M.
منابع مشابه
Adsorptive Cathodic Stripping Voltammetric Determination of Ciprofloxacin in Bulk Powder, Pharmaceutical Dosage Forms and Urine
Purpose: To investigate the electro-reduction behaviour and determination of ciprofloxacin using a hanging mercury drop electrode. Methods: Cyclic voltammograms of ciprofloxacin recorded in Britton – Robinson buffers pH 2 – 5 exhibit a single irreversible cathodic peak. The dependence of the peak current and peak potential values on buffer (nature, pH and concentration) and accumulation conditi...
متن کاملSimultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid
In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...
متن کاملAdsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملAdsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملDetermination of ultra trace of thiosemicarbazide by adsorptive stripping voltammetric method
In the present work, an adsorptive stripping voltammetric method using a hanging mercurydrop electrode (HMDE) was described in order to determine the ultra trace of thiosemicarbazidein different real samples. The method is based on accumulation of thiosemicarbazide on mercuryelectrode. The potential was scanned to the negative direction and the differential pulse strippingvoltammograms were rec...
متن کامل