Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution.

نویسندگان

  • H H Woltjer
  • H J Bogaard
  • G J Scheffer
  • H I van der Spoel
  • M A Huybregts
  • P M de Vries
چکیده

Since its introduction by Kubicek and colleagues, impedance cardiography has been suggested as a non-invasive, simple, safe and cost-effective method of measuring stroke volume. Several controversial reports on its validity have been published. Pitfalls of this method included the nature of the electrode system and the validity of the equations. Therefore, the purpose of this study was to compare two different spot electrode arrays and the two most frequently used stroke volume equations with each other and with thermodilution. In 37 patients, 24-36 h after cardiac surgery, we performed simultaneous measurements of stroke volume with impedance cardiography (SVIC) and with thermodilution (SVTD). SVIC was obtained using the lateral spot (LS) electrode array, according to Bernstein, and a newly proposed modified semi-circular (MSC) spot electrode array. The equations of Kubicek and Sramek-Bernstein were used to calculate SVIC. The Sramek-Bernstein equation was valid only when the LS array was used; the Kubicek equation determined SVTD correctly only when the MSC array was used. However, a considerably better correlation and agreement (mean difference (2 SD)) was found between SVIC and SVTD for the latter (r = 0.90, 0.5 (17.1) ml vs r = 0.64, -4.9 (31.8) ml for the Sramek-Bernstein equation). We conclude that the most valid measurement of stroke volume using impedance cardiography was obtained when the MSC array was used together with Kubicek's equation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Intra-aortic Balloon Counterpulsation Impact on Stroke Volume using a Non-invasive Technique: Impedance Cardiography

Evaluation of the haemodynamic state of patients with acute myocardial infarction (AMI) has always been a subject of interest for clinicians. The search of optimal methods and grounding of the indications for the monitoring of central hemodynamics conditioned the introduction of invasive methods for evaluation of hemodynamics into clinical practice in 1970. The method of intermittent thermodilu...

متن کامل

قلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی

 Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...

متن کامل

Temporal stability of ambulatory stroke volume and cardiac output measured by impedance cardiography.

UNLABELLED Recently, devices have become available that allow non-invasive measurement of stroke volume and cardiac output through ambulatory thorax impedance recording. If such recordings have adequate temporal stability, they offer great potential to further our understanding of how repeated or chronic cardiovascular activation in response to naturalistic events may contribute to cardiovascul...

متن کامل

Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography.

The evaluation of the hemodynamic state of the severely ill patient is a common problem in emergency medicine. While conventional vital signs offer some insight into delineating the circulatory pathophysiology, it is often impossible to determine the true clinical state from an analysis of blood pressure and heart rate alone. Cardiac output measurements by thermodilution have been the criterion...

متن کامل

Stroke volume during orthostatic challenge: comparison of two non-invasive methods.

BACKGROUND Real time non-invasive determination of stroke volume (SV) is important to astronaut orthostatic testing. We compared simultaneous estimates of SV calculated from peripheral pulse waveforms with a more conventional non-invasive technique. METHODS Ten men and nine women completed 12-min protocols. The relative change (% delta) in beat-to-beat SV was estimated non-invasively from cha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 77 6  شماره 

صفحات  -

تاریخ انتشار 1996