Comparison between the Hybrid Capture II Test and an SPF1/GP6+ PCR-based assay for detection of human papillomavirus DNA in cervical swab samples.

نویسندگان

  • Shang-Lang Huang
  • Angel Chao
  • Swei Hsueh
  • Fang-Yu Chao
  • Chu-Chun Huang
  • Jung-Erh Yang
  • Ching-Yu Lin
  • Chiu-Cho Yan
  • Hung-Hsueh Chou
  • Kuan-Gen Huang
  • Huei-Jean Huang
  • Tzu-I Wu
  • Mao-Jung Tseng
  • Jian-Tai Qiu
  • Cheng-Tao Lin
  • Ting-Chang Chang
  • Chyong-Huey Lai
چکیده

We compared the efficacy of human papillomavirus (HPV) DNA detection between a PCR-based genechip (Easychip HPV Blot [hereafter referred to as HPV Blot]; King Car, Taiwan) method and Hybrid Capture II (HCII; Digene, Gaithersburg, MD) in women with previous normal (n = 146) or abnormal (> or =atypical squamous cells of undetermined significance [ASCUS] [n = 208]) cytology. A total of 354 cervical swab samples were collected for HPV DNA assay by both HCII and SPF1/GP6+ PCR followed by HPV Blot tests. Colposcopy-directed biopsy was performed if clinically indicated. Of the 354 samples, HPV-positive rates by these two methods (HCII and HPV Blot) were 12.6% and 18.2% in 143 normal samples, 36.2% and 45.7% in 105 ASCUS samples, 57.4% and 57.4% in 94 low-grade squamous intraepithelial lesion samples, and 83.3% and 75.0% in 12 high-grade squamous intraepithelial lesion samples, respectively. The concordance of HPV Blot and HCII was 80.8% (286/354), and the agreement between the methods (kappa value, 0.68) was substantial. Discrepancies were further investigated by at least one of the following three methods: direct sequencing, type-specific PCR, and HPV Blot genotyping of cervical biopsy tissue. In the 15 HCII-positive samples, HPV Blot detected only non-HCII HPV genotypes; results of further verification methods were consistent with the latter test in the 15 samples. Of the 20 samples with HCII-negative and HPV Blot-positive results, 18 were found to contain the 13 HCII high-risk genotypes by verification methods. In only 16.7% (3/18) of the HCII-positive but HPV Blot-negative samples, further studies detected the 13 HCII genotypes. We conclude that HPV Blot seemed comparable to HCII for detection of HPV DNA in cervical swab samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hybrid capture II, a new sensitive test for human papillomavirus detection. Comparison with hybrid capture I and PCR results in cervical lesions.

AIM To test a new assay for the detection of human papillomavirus (HPV) DNA, hybrid capture II (HC II), compared with the previous commercialized hybrid capture I (HC I) and polymerase chain reaction (PCR) results on cervical scrapes from fresh cone excision biopsy samples. METHODS The three methods were used on cervical scrapes from 42 fresh cone excision biopsy samples. There were nine meta...

متن کامل

Comparison between the Hybrid Capture II test and a PCR-based human papillomavirus detection method for diagnosis and posttreatment follow-up of cervical intraepithelial neoplasia.

Human papillomavirus (HPV) infection is the major cause of cervical cancer and its precursor, cervical intraepithelial neoplasia (CIN), and HPV testing has therefore been proposed for improved triaging and follow-up of women treated for CIN. We compared two common HPV DNA detection tests (Hybrid Capture II [HCII] and PCR-enzyme immunosorbent assay (EIA) using the primers GP5+/GP6+ followed by H...

متن کامل

Comparison of PCR- and hybrid capture-based human papillomavirus detection systems using multiple cervical specimen collection strategies.

This study compared the performances of three human papillomavirus (HPV) detection tests with specimens collected by three alternative procedures. The HPV tests included the Hybrid Capture Tube test (HCT), the microplate-based Hybrid Capture II test (HC II), and the MY09-MY11 L1 consensus primer PCR-based assay. Initial cervical specimens were collected from study subjects with a broom device, ...

متن کامل

Comparison of the Seeplex HPV4A ACE and the Cervista HPV assays for the detection of HPV in hybrid capture 2 positive media

OBJECTIVE To validate the efficacy of Seeplex HPV4A ACE for the detection of high-risk (HR) human papillomavirus (HPV) and HPV 16 and/or HPV 18 genotypes as compared to the PCR method and the Cervista HPV assays in cervical swab samples. METHODS Besides liquid-based cytology, additional 97 cervical swab samples were collected for HPV genotyping by HPV4A ACE, Cervista HPV assays, and PCR metho...

متن کامل

Comparison of human papillomavirus detection and typing by cycle sequencing, line blotting, and hybrid capture.

We compared the results of human papillomavirus (HPV) detection and typing from 781 cervical samples assayed by three methods: L1 consensus PCR followed by cycle sequencing, L1 consensus PCR with biotinylated primers followed by hybridization to a line blot, and Hybrid Capture assay. Both PCR assays used L1 consensus PCR with primers MY09 and MY11. We evaluated the amplification efficiencies of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 44 5  شماره 

صفحات  -

تاریخ انتشار 2006