Particle size selection device for use with the Turbohaler.
نویسندگان
چکیده
BACKGROUND Drug deposited within the upper airways of patients using dry powder inhalers does not contribute to the therapeutic effect but can result in unwanted local side effects and, when swallowed, may contribute to systemic effects. A chamber has been devised which uses the centrifugal force generated by the Turbohaler to remove large "non-respirable" particles with a view to minimising deposition in the upper airway. An in vitro study was performed to determine whether such a chamber could reduce the dose contained in coarse particles without having a significant effect on the "respirable dose". METHODS The mouthpiece of a 200 micrograms Turbohaler was modified to allow a small volume chamber to be attached. The particle size distribution generated by the Turbohaler was assessed using a multi-stage liquid impinger with a flow rate of 60 l/min. The quantity of drug on each stage was quantified using an ultraviolet spectrophotometric technique. For each experiment 10 actuations were used to ensure adequate quantities of drug on each stage. Particles depositing on stages 3 + 4 have a diameter of < 6.8 microns and are arbitrarily referred to as the "respirable dose". The particle size distribution obtained using the Turbohaler (n = 10) was compared with that from the Turbohaler+ chamber (n = 11). RESULTS The addition of the chamber resulted in the mean (SD) dose contained in larger "non-respirable" particles depositing on stages 1 + 2 being reduced from 52.2 (12.3) to 29.6 (6.9) micrograms per actuation. However, the chamber did not affect the "respirable" dose. The dose contained in particles with a diameter of < 6.8 microns from the standard Turbohaler was 91.1 (8.9) micrograms compared with 82.4 (18.6) micrograms when used with the chamber. CONCLUSIONS These results indicate that it is possible to devise an effective particle size selection device for the Turbohaler. It may be possible to produce such devices for other dry powder inhalers, although the design would need to be tailored to each particular device.
منابع مشابه
An alternative aerosol delivery system for amiloride.
BACKGROUND The advent of novel treatments such as aerosolized amiloride are potentially useful additions to the therapeutic options available for the treatment of cystic fibrosis. Unfortunately, amiloride and other aerosolized drugs such as antibiotics are generally administered via jet nebulisers which are time consuming to use, and thus limit the acceptance and efficacy of these forms of trea...
متن کاملComparison of elderly people's technique in using two dry powder inhalers to deliver zanamivir: randomised controlled trial.
OBJECTIVE To determine whether elderly people can learn to use the inhaler used to deliver zanamivir (Relenza Diskhaler) as effectively as the Turbohaler and to identify which aspects of inhaler technique are most problematic. DESIGN Randomised, controlled, intervention study. SETTING Wards for acute elderly care in a large district general hospital. PARTICIPANTS 73 patients who were unfa...
متن کاملEffect of Flow Rate on In Vitro Aerodynamic Performance of NEXThaler® in Comparison with Diskus® and Turbohaler® Dry Powder Inhalers
BACKGROUND European and United States Pharmacopoeia compendial procedures for assessing the in vitro emitted dose and aerodynamic size distribution of a dry powder inhaler require that 4.0 L of air at a pressure drop of 4 kPa be drawn through the inhaler. However, the product performance should be investigated using conditions more representative of what is achievable by the patient population....
متن کاملEffect of Surfactant Type, Cholesterol Content and Various Downsizing Methods on the Particle Size of Niosomes
The present study was conducted to investigate the performance of different size reduction techniques including probe sonication, extrusion, and high pressure homogenization for nanosizing of niosomes. Also, the effects of cholesterol content and surfactant type on the size and poly dispersity index (PDI) of the formulations were evaluated. Various niosomal formulations composed of Brij 72, Spa...
متن کاملEffect of Surfactant Type, Cholesterol Content and Various Downsizing Methods on the Particle Size of Niosomes
The present study was conducted to investigate the performance of different size reduction techniques including probe sonication, extrusion, and high pressure homogenization for nanosizing of niosomes. Also, the effects of cholesterol content and surfactant type on the size and poly dispersity index (PDI) of the formulations were evaluated. Various niosomal formulations composed of Brij 72, Spa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 51 5 شماره
صفحات -
تاریخ انتشار 1996