Comparison of Partial Discharge Behavior with Alternating Current and Damped Alternating Current at Different Frequencies

نویسندگان

  • M. Wild
  • S. Tenbohlen
چکیده

This article presents investigations of partial discharges (PD) in a high voltage cable system using different voltage shapes and frequencies. The two voltage sources which were used for energizing the cable system, are 50 Hz alternating current (AC) generated by a high voltage transformer and damped alternating current (DAC). Both systems can be used for PD detection with use of a standard PD measurement circuit consisting of coupling capacitor and coupling device with digital signal processing. With the help of an artificial PD source, the PD level is compared for AC and DAC and also the phase relation of PD for both methods is shown. Moreover comparison of partial discharge inception voltage (PDIV) for both energizing methods is described and measurements are shown. The measurements with the DAC source were performed at three different frequencies. Changing the resonant frequency is handled by adding capacitors in parallel to the cable system to increase the overall capacitance. Keywords—partial discharge, high voltage cable, PD detection, damped AC, artificial PD, PD measurement

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Untersuchung von Teilentladungsverhalten mit Wechselspannung und gedämpfter Wechselspannung Investigation of partial discharge behaviour with alternating current and damped alternating current

This article shows investigations of partial discharge (PD) in a high voltage cable system using different voltage shapes. The two sources which were used for energizing the cable system, are 50 Hz alternating current (AC) generated by a high voltage transformer and damped alternating current (DAC). Both systems can be used for PD detection with use of a standard PD measurement circuit existing...

متن کامل

Thick Film Deposition of Carbon Nanotubes by Alternating Electrophoresis

Electrophoretic deposition of carbon nanotubes (CNTs) using alternating current electric fields (0.01-1000 Hz) is reported. Pure acetone was used as suspending medium. Two parallel gold electrodes were used as depositing substrate. The effect of depositing parameters such as frequency and three waveforms (sinusoidal, rectangular and triangular) on deposit yield was investigated. According to ou...

متن کامل

Effect of Transcranial Alternating Current Stimulation on Anxiety and Hemodynamic Response in Patients Undergoing Surgery: A Double-Blind Controlled Clinical Trial

Background: Pre-op anxiety has adverse effects on the patientchr('39')s anesthesia and treatment. Currently, electrical interventions are widely used as non-invasive methods to control pre-op anxiety and may have advantages as compared with medical therapies. This study aimed to determine the effect of transcranial alternating current stimulation on anxiety and hemodynamic response of patients ...

متن کامل

Asymmetric Rectangular Waveform in Stimulation with High Frequency Alternating Current Reduces the Threshold for Neural Conduction Block

Introduction Abnormal neural impulses in the nervous system may lead to various diseases and disabilities. High frequency alternating currents (HFAC) has been used to block the propagation of such impulses and improve the symptoms or disabilities. The technique is safe, reversible, and relatively selective, and its reliability, the optimum stimulation parameters, and elimination of the onset re...

متن کامل

INVESTIGATING THE ROLE OF CAUSATIVIZATION IN OVERPASSIVIZATION OF UN-ACCUSATIVE VERBS BY IRANIAN ENGLISH MAJORS

The current study aims at exploring the role of causativization as one of the causes stated in the literature for overpassivization of English unaccusatives in an Iranian context.The study was conducted using three data collection procedures, an Oxford Placement Test, a Grammaticality Judgment Task, and a Production Task. The results revealed that causativization errors with non-alternating una...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014