Breast phantom with silicone implant for evaluation in conventional mammography
نویسندگان
چکیده
With the increased incidence of cancer and a similarly increased number of surgeries for insertion of silicone breast implants, it is necessary to assess the effect of such material within the breast tissue, particularly in mammography, because of the reduction in the power of breast cancer diagnosis. In this work, we introduce a breast phantom with silicone implants in order to evaluate the influence of the implant on the visibility of the main mammographic findings: fibers, microcalcifications and tumor masses. In this proposed phantom, the breast tissue was simulated using gel paraffin. In the optical density of phantom mammograms with implants, a reduction in breast tissue visibility was seen corresponding to 23% when compared to a phantom without silicone implants. This poor visibility was due to the X-ray beam scattering on silicone material; this effect produced a loss of visibility in the areas adjacent to the implant. It is expected that the proposed phantom model may be used as a device for the establishment of a technical standard for these types of procedures.
منابع مشابه
Role of mammography to assess complications of silicone gel breast implants
W Peters, D Smith, H Grosman, V Fornasier. Role of mammography to assess complications of silicone gel breast implants. Can J Plast Surg 1995;3(3):150-156. Mammography is not accurate to predict implant rupture in most patients. Its sensitivity rate is only 11 to 16%. However, two mammographic findings appear to suggest implant rupture: the appearance of large areas of implant herniation, and t...
متن کاملEvaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation
Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...
متن کاملCosmetic Case Report Rupture of a Hydrogel-Filled Breast Implant
In the early 1960s, Cronin and Gerow began to use a silicone bag filled with silicone gel for breast augmentation. Since then, researchers have been looking for different filler materials. An ideal prosthesis does not induce any tissue reaction, is stable, gives the breast a natural appearance, and is radiolucent during mammography. In case of rupture of the envelope, the filler material should...
متن کاملEvaluation of the rupture of silicone breast implants by mammography, ultrasonography and magnetic resonance imaging in asymptomatic patients: correlation with surgical findings.
CONTEXT Different imaging methods can identify the integrity of breast implants and also the extent of possible silicone leakage. Mammography, ultrasonography and magnetic resonance imaging are often used to evaluate the integrity of breast implants, usually in patients that are symptomatic for rupture. A group of clinically asymptomatic patients was taken as a sample. These patients wanted to ...
متن کاملEvaluation of the Rupture of Silicone Breast Implants by Mammography
OBJECTIVE: The purpose of this study was to compare the efficacies of mammography, sonography and MR imaging in the detection of breast implant rupture of an asymptomatic population. MATERIALS AND METHODS: We prospectively evaluated 83 breast implants in 44 asymptomatic patients who subsequently had implants removed by a surgeon to determine sensitivity and specificity of mammography, ultrasono...
متن کامل