[Hybrid material contact lens in keratoconus and myopic astigmatism patients].

نویسندگان

  • Fernando Leal
  • César Lipener
  • Maria Regina Chalita
  • Ricardo Uras
  • Mauro Campos
  • Ana Luisa Höfling-Lima
چکیده

PURPOSE To evaluate comfort and visual performance in relation to two different used contact lens types: hybrid material (HM) and rigid-gas-permeable (RGP), in patients with regular myopic astigmatism and with keratoconus. METHODS A randomized, double masked, prospective study of 22 patients with the diagnosis of myopic astigmatism (8 with myopic astigmatism and 14 with keratoconus) was conducted. Fifteen patients were female and 7 were male, and mean age was: 32.13 +/- 8.12 years. In one of the eyes a rigid-gas-permeable contact lens was adapted (DK 30), and in the other a hybrid material contact lens was adapted (DK 23). All patients were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, tear break-up time, best corrected visual acuity with the Bailey-Lovie scale adapted for 4 meters, functional acuity contrast test (FACT) and wavefront analysis. RESULTS In relation to comfort, there was no association with the evaluated contact lens type (p=0.350). There was a variation in comfort level during the first 7 days. The visual acuity increased between the 7th and the 15th day of adaptation. Visual acuity stabilized right after this period. The visual acuity did not show differences in relation to the studied lens type. It was verified that there was no difference in the tear break-up time (p=0.989) in relation to the studied lenses type and there was a decrease in the tear break-up time (p=0.001) when we compared the measurement before the use of the lenses and 2 months after their use. There was no difference in contrast sensitivity in the used lens type and between each type and the use of glasses (p<0.047). High order aberrations decreased significantly when comparing patients with and without contact lenses, except for spherical and coma aberrations (p=0.394). CONCLUSION Comfort and visual performance when comparing hybrid material and rigid-gas-permeable contact lenses did not show any significant difference in the patients or when compared separately in regular myopic astigmatism and in keratoconus patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial Visual Rehabilitation Using a Toric Implantable Collamer Lens in a Patient with Keratoconus: A Case Report with 20 Months of Follow-up

We report the case of a 37-year-old man with a high myopic keratoconus eye that was treated with a posterior chamber toric implantable collamer lens (ICL) in Korea. The patient had a history of contact lens intolerance and did not want to have a corneal transplantation. His uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity were 0.02 and 0.4 in the left eye, respectivel...

متن کامل

Contact Lens Visual Rehabilitation in Keratoconus and Corneal Keratoplasty

Keratoconus is the most common corneal distrophy. It's a noninflammatory progressive thinning process that leads to conical ectasia of the cornea, causing high myopia and astigmatism. Many treatment choices include spectacle correction and contact lens wear, collagen cross linking, intracorneal ring segments implantation and finally keratoplasty. Contact lenses are commonly used to reduce astig...

متن کامل

Comparison of Contact Lens Corrected Quality of Vision and Life of Keratoconus and Myopic Patients

PURPOSE To compare and analyze changes in vision quality, subjective symptoms, and psycho-social satisfaction in keratoconus and myopic patients following the wearing of contact lenses. METHODS This study enrolled 25 keratoconus and 25 myopic patients with corrected vision over 0.8 according to the Snellen chart due to treatment with contact lenses. Patients were surveyed prior to the wearing...

متن کامل

Toric implantable collamer lens for high myopic astigmatism in keratoconic patients after six months.

BACKGROUND The aim was to evaluate the safety, efficacy, stability and predictability of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia and myopic astigmatism associated with keratoconus. METHODS The unaided vision and visual acuity, refraction and adverse events were measured in 22 keratoconic eyes of 14 patients after using an implantable ...

متن کامل

Comparison of Clinical Outcomes of Same-size Grafting between Deep Anterior Lamellar Keratoplasty and Penetrating Keratoplasty for Keratoconus

PURPOSE To compare the clinical outcomes between deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PKP) with same-size grafts in patients with keratoconus. METHODS Medical records of 16 eyes from 15 patients treated from June 2005 through April 2011 were retrospectively reviewed. Patients with contact lens intolerance or who were poor candidates for contact lens fitting...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 70 2  شماره 

صفحات  -

تاریخ انتشار 2007