Innovative shear connection with composite dowels – verification using push-out test

نویسنده

  • VERONIKA VÁCLAVÍKOVÁ
چکیده

In recent years many research on composite beams with innovative shear transmission with composite dowels have been conducted and innovative composite constructions have been built. One of the common types of shear connection is the method of rolled girders encased in a concrete slab. The combination of such method and pcb (precast composite beam) technology is called pcb-W (precast composite beam – coupled in web) technology which has been developing since 2003 in Germany. The longitudinal shear force is transformed by composite dowels instead of headed studs. The standard push-out tests according to EC4 have been performed at the Brno University of Technology to verify the behavior of the composite connection. The bearing capacity of the concrete dowel is mainly affected by reinforcement area. The minimum or recommended area of the reinforcement is given by [7]. If greater bearing capacity of concrete dowel was required, it would be possible to employ more reinforcement bars or use reinforcement bars of greater parameter. However, we have to consider the armoring and mounting of the structure, which is more complicated the more reinforcement we use. For this reason, nine specimens were prepared for the standard push-out tests, 3 specimens with common concrete and recommended area of reinforcement, 3 specimens with fiber reinforced concrete and reduced area of reinforcement and 3 specimens with fiber reinforced concrete and no additional reinforcement. The reason of this research is to lower the area of reinforcement bars in composite dowels and make the process less laborious. Key-Words: Composite structures, push-out test, pcb-W technology, steel fiber reinforced concrete

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Load-carrying behaviour of steel-to-timber dowel connections

This paper details tests on steel-wood-steel connections with thin dowels carried out at the University of British Columbia in Vancouver, Canada. Connections configurations were selected in such a way that the influence of the main parameters such as dowel slenderness ratio, dowel strength, fastener spacing and end distance and the number of dowels could be studied. An important issue of the pa...

متن کامل

Testing and numerical modelling of Steel-Concrete-Steel with stud bolts connectors subject to push-out loading

Steel-concrete-steel (SCS) sandwich panels are composed of two steel plates with low thicknesses and high densities and strengths and one thick layer between both plates with low strength and density known as core that is composed of concrete. Cohesive material-epoxy resin or shear connectors are usually used to connect the plates to the concrete core. SCS sandwich composites are being develope...

متن کامل

Effect of type and distribution of shear studs on the behavior of composite steel-concrete shear walls

In this research in-plane shear Behavior of composite steel-concrete shear walls was investigated considering the Effects of steel plates thickness, spaces between shear studs, shape and type of shear studs and existing of minimum reinforcement in wall section. Several finite element models were analyzed and Numerical results of two models were taken under verification with existent experimenta...

متن کامل

Pre-Cracked Concrete Shear Strengthened with External CFRP Strips

In reinforced concrete design, there are situations where transfer of shear across a specific plane needs to be considered. Examples of such situation include corbels, bearing shoes, ledger beam bearing, and a host of connection between precast concrete elements. In this study, the shear transfer behavior of reinforced concrete is investigated experimentally by conducting test on 6 precracked p...

متن کامل

Dynamic fibre push-out test applied to metal-matrix composites

The dynamic fiber/matrix interface strength for a silicon-carbide-fiber-reinforced, titanium-alloy metal-matrix composite was measured by impacting the end of a fiber extending through a thin specimen with a diamond-tipped projectile at ~2 m/s. The matrix surrounding the distal end of the fiber was supported on the end of a Hopkinson bar fabricated from hypodermic needle tubing, and an interfer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017