Direct and simultaneous determination of molybdenum and vanadium in sea-water using a multielement electrothermal atomic absorption spectrometer
نویسندگان
چکیده
Direct and simultaneous determinations of Mo and V in seaemission spectrometry (ICP-AES)26 and mass spectrometry water using a multi-element electrothermal atomic absorption (ICP-MS),27,28 X-ray fluorescence spectrometry,29 cathodic spectrometer (Perkin-Elmer SIMAA 6000) are described. stripping voltammetry (CSV)30 and multi-element electrotherThree kinds of chemical modifier [Mg(NO 3 ) 2 , Pd(NO 3 ) 2 and mal atomic absorption spectrometry (ETAAS).31–36 Each a mixture of both] were tested. A simple calibration curve instrument has its particular advantages and disadvantages. method could be used to determine Mo in sea-water using Pd The most important commercially available multi-element or a mixture of Pd and Mg as the chemical modifier. A instruments for trace elemental determination are ICP-based. standard additions method was used to determine V and to The applicability of ICP-based instruments has been limited determine Mo and V simultaneously in sea-water. The by the difficulty in dealing with samples with high salt concendetection limits were 0.35–0.60 mg l−1 for Mo. The detection trations and the need for relatively large sample volumes. limit for V in this work (0.32–0.51 mg l−1) is much lower than Consequently, separation or preconcentration of the analytes those reported in the literature (18–50 mg l−1), such that direct from the matrix prior to the measurement is necessary. determination of V in unpolluted sea-water (<2 mg l−1) by Although ICP-MS has emerged as a method with a power of ETAAS is possible. The RSDs for the simultaneous detection which is at least comparable to that of ETAAS, the determination of Mo and V in nearshore or open ocean seaMS detector is complex and expensive, which has limited the water are ∏11% using a mixture of Pd and Mg as the widespread use of ICP-MS in routine work. In recent years, chemical modifier. The accuracy of the method for Mo many kinds of multi-element ETAAS instrument have been determination was confirmed by the analysis of two kinds of developed and become commercially available, hence the applicertified reference sea-water. There is no certified value of V cations of ETAAS in multi-element determinations are of great provided for these reference sea-water samples. The interest.31–36 experimentally determined of V concentrations were compared Several papers have appeared concerned with the direct with values reported in the literature. determination of Mo3,4,37,38 and V38–40 in sea-water by ETAAS. The direct determination of Mo in sea-water by ETAAS has
منابع مشابه
Preconcentration of Cu(II)with magnetic nanocomposite sorbentsprior to determination by Flame Atomic Absorption Spectrometer
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cu2+ in water samples .In this paper, Chitosan was used to encapsulate nano-Fe3O4 and produce a nano-Fe3O4-CHITOSAN sorbent based new sorbent was prepared. This was treated with ethylenediamine (ED) in another solvent-free procedure for the formation of a novel nano-Fe3O4-Chitosan-ED.Flame atomic abs...
متن کاملDetermination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملPreconcentration of Cu(II)with magnetic nanocomposite sorbentsprior to determination by Flame Atomic Absorption Spectrometer
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Cu2+ in water samples .In this paper, Chitosan was used to encapsulate nano-Fe3O4 and produce a nano-Fe3O4-CHITOSAN sorbent based new sorbent was prepared. This was treated with ethylenediamine (ED) in another solvent-free procedure for the formation of a novel nano-Fe3O4-Chitosan-ED.Flame atomic abs...
متن کاملMultielement determination of cadmium and lead in urine by simultaneous electrothermal atomic absorption spectrometry with an end-capped graphite tube.
A method for the multielement determination of cadmium and lead in urine is proposed by simultaneous electrothermal atomic absorption spectrometry (SIMAAS) with an end-capped transversely heated graphite atomizer (EC-THGA). The best conditions for cadmium and lead determination were obtained in the presence of NH4H2PO4 as a chemical modifier, using 500 degrees C and 1800 degrees C as the pyroly...
متن کاملPreconcentration and Determination of Lead for Trace Levels in Water and Wastewater Samples by Vortex-Assisted Microextraction Using TPAS as a New Synthetic Complexing Agent with Electrothermal Atomic Absorption Spectroscopy Detection
A simple and rapid solidified vortex assisted 1-undecanol based liquid-liquid microextraction technique was proposed for preconcentration of trace levels of lead ions. The extraction solvent (1-undecanol) was dispersed into the aqueous samples by the assistance of vortex agitator. 100 µL of 1-undecanol containing ethyl (2Z)-3-[(5-chloro-7-methyl[1,3]thiazolo[5,4-d]pyrimidi...
متن کامل