Tendon motion and strain patterns evaluated with two-dimensional ultrasound elastography.

نویسندگان

  • Laura A Chernak
  • Darryl G Thelen
چکیده

The purpose of this study was to evaluate the use of 2D ultrasound elastography to assess tendon tissue motion and strain under axial loading conditions. Four porcine flexor tendons were cyclically loaded to 4% peak strain using a servo hydraulic test system. An ultrasound transducer was positioned to image a longitudinal cross-section of the tendon during loading. Ultrasound radiofrequency (RF) data were collected at 63 frames per second simultaneously with applied force and crosshead displacement. A grid of nodes was manually positioned on an ultrasound image of the unloaded tendon. Small kernels (2×1 mm) centered at each node were then cross-correlated with search regions centered at corresponding nodal locations in the subsequent frame. Frame-to-frame nodal displacements were defined as the values that maximized the normalized cross-correlations. This process was repeated across all frames in the loading cycle, providing a measurement of the 2D trajectories of tissue motion throughout the loading cycle. The high resolution displacement measures along the RF beam direction were spatially differentiated to estimate the transverse (relative to tendon fibers) tissue strains. The nodal displacements obtained using this method were very repeatable, with average along-fiber trajectories that were highly correlated (average r=0.99) with the prescribed crosshead displacements. The elastography transverse strains were also repeatable and were consistent with average transverse strains estimated via changes in tendon width. The apparent Poisson's ratios (0.82-1.64) exceeded the incompressibility limit, but are comparable to values found for tendon in prior experimental and computational studies. The results demonstrate that 2D ultrasound elastography is a promising approach for noninvasively assessing localized tissue motion and strain patterns.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer Vision Elastography

This thesis is concerned with developing a two-dimensional (2D) ultrasound speckle tracking technique to quantify 2D axial and lateral strain fields for studying tissue dynamics. Knowledge of tissue displacement to infer strain characteristics is of major clinical importance. In part, this is due to the lack of simple and accurate non-invasive techniques to measure in vivo strain. The establish...

متن کامل

The AutoQual ultrasound elastography method for quantitative assessment of lateral strain in post-rupture Achilles tendons.

This paper presents the AutoQual elastography method: a novel algorithm that improves the quality of 2D displacement field calculation from ultrasound radio frequency (RF) sequences of acutely ruptured Achilles tendons to determine image-lateral strain fields and has potential use for ligaments and muscles. This method uses 2D bicubic spline interpolation of the RF signal, Quality Determined Se...

متن کامل

Ultrasound elastography for imaging tendons and muscles

Ultrasound elastography is a recently developed ultrasound-based method which allows the qualitative or quantitative evaluation of the mechanical properties of tissue. Strain (compression) ultrasound elastography is the commonest technique performed by applying mild compression with the hand-held transducer to create real-time strain distribution maps, which are color-coded and superimposed on ...

متن کامل

Analisys of pectoralis major tendon in weightlifting athletes using ultrasonography and elastography

OBJECTIVE To evaluate tendinopathy of the pectoralis major muscle in weightlifting athletes using ultrasound and elastography. METHODS This study included 20 patients, 10 with rupture of the pectoralis major muscle and 10 control patients. We evaluated pectoralis major muscle contralateral tendon with ultrasonographic and elastography examinations. The ultrasonographic examinations were perfo...

متن کامل

Sonoelastography in the musculoskeletal system: Current role and future directions

Ultrasound is an essential modality within musculoskeletal imaging, with the recent addition of elastography. The elastic properties of tissues are different from the acoustic impedance used to create B mode imaging and the flow properties used within Doppler imaging, hence elastography provides a different form of tissue assessment. The current role of ultrasound elastography in the musculoske...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 45 15  شماره 

صفحات  -

تاریخ انتشار 2012