Compression-rate-dependent nonlinear mechanics of normal and impaired porcine knee joints

نویسندگان

  • Marcel Leonardo Rodriguez
  • LePing Li
چکیده

BACKGROUND The knee joint performs mechanical functions with various loading and unloading processes. Past studies have focused on the kinematics and elastic response of the joint with less understanding of the rate-dependent load response associated with viscoelastic and poromechanical behaviors. METHODS Forty-five fresh porcine knee joints were used in the present study to determine the loading-rate-dependent force-compression relationship, creep and relaxation of normal, dehydrated and meniscectomized joints. RESULTS The mechanical tests of all normal intact joints showed similar strong compression-rate-dependent behavior: for a given compression-magnitude up to 1.2 mm, the reaction force varied 6 times over compression rates. While the static response was essentially linear, the nonlinear behavior was boosted with the increased compression rate to approach the asymptote or limit at approximately 2 mm/s. On the other hand, the joint stiffness varied approximately 3 times over different joints, when accounting for the maturity and breed of the animals. Both a loss of joint hydration and a total meniscectomy greatly compromised the load support in the joint, resulting in a reduction of load support as much as 60% from the corresponding intact joint. However, the former only weakened the transient load support, but the latter also greatly weakened the equilibrium load support. A total meniscectomy did not diminish the compression-rate-dependence of the joint though. CONCLUSIONS These findings are consistent with the fluid-pressurization loading mechanism, which may have a significant implication in the joint mechanical function and cartilage mechanobiology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Functional Fatigue on Landing Mechanics using Landing Error Scoring System (LESS)

One of the factors affecting jump-landing patterns is fatigue. Fatigue is an inevitable component of physical activity, hence the aim of the present study was to investigate the effect of functional fatigue on landing mechanics through Landing Error Scoring System (LESS).Fourteen male college students with a mean age of 22±2 years, weight of 68.3±7.2 kg and height of 174±4 were randomly divi...

متن کامل

Dynamics of a Running Below-Knee Prosthesis Compared to Those of a Normal Subject

The normal human running has been simulated by two-dimensional biped model with 7 segments. Series of normal running experiments were performed and data of ground reaction forces measured by force plate was analyzed and was fitted to some Fourier series. The model is capable to simulate running for different ages and weights at different running speeds. A proportional derivative control algorit...

متن کامل

Evaluation of hyperelastic models for the non-linear and non-uniform high strain-rate mechanics of tibial cartilage.

Accurate modeling of the high strain-rate response of healthy human knee cartilage is critical to investigating the mechanism(s) of knee osteoarthritis and other cartilage disorders. Osteoarthritis has been suggested to originate from regional shifts in joint loading during walking and other high strain-rate physical activities. Tibial plateau cartilage under compression rates analogous to walk...

متن کامل

How three methods for fixing a medial meniscal autograft affect tibial contact mechanics.

We evaluated three methods for fixing a medial meniscal autograft to determine which method restored tibial contact mechanics closest to normal. The contact mechanics (maximum pressure, mean pressure, contact area, and location of the center of maximum pressure) of the medial tibial articular surface were determined using pressure-sensitive film while knee specimens were loaded in compression t...

متن کامل

Biomechanical evaluation of human and porcine auricular cartilage.

OBJECTIVES/HYPOTHESIS The mechanical properties of normal auricular cartilage provide a benchmark against which to characterize changes in auricular structure/function due to genetic defects creating phenotypic abnormalities in collagen subtypes. Such properties also provide inputs/targets for auricular reconstruction scaffold design. Several studies report the biomechanical properties for sept...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017