[Low sensitivity of the echocardiograph compared with contrast transcranial Doppler in right-to-left shunt].

نویسندگان

  • P Martínez-Sánchez
  • J Medina-Báez
  • M Lara-Lara
  • J Oliva-Navarro
  • R Cazorla-García
  • G Ruiz-Ares
  • M Martínez-Martínez
  • B Fuentes
  • E Díez-Tejedor
چکیده

BACKGROUND Contrast transcranial Doppler (c-TCD) has a high sensitivity for detecting right-to-left shunt (RLS), and is probably higher than transthoracic echocardiography (TTE) and comparable with transesophageal echocardiography (TEE). OBJECTIVE To evaluate the accuracy of echocardiography (TTE and TEE) to detect RLS compared to c-TCD. MATERIAL AND METHODS Observational study of patients <55 years old with cerebral ischaemia of undetermined origin (2007-2009). All underwent c-TCD monitoring to detect RLS, at rest and after Valsalva manoeuvre (VM). The TTE and TEE were performed when indicated by our cerebrovascular protocol. The accuracy of TTE and TEE for detecting RLS was calculated by comparing them with c-TCD. RESULTS A total of 115 patients with c-TCD, mean age 43.3 (SD 10.3) years, 51.3% male. The TTE was performed in 102, and TEE in 81, patients. RLS detection was higher with c-TCD than with TTE (67.6% vs. 22.5%, P=.001) or TEE (77.8% vs. 53.1%, P=.001). The TTE, compared with c-TCD after MV showed: sensitivity 31.8%, specificity 96.9%, positive predictive value (PPV) 95.6%, negative predictive value (NPV) 40.5% and accuracy 52.9% to detect RLS. TEE, compared with c-TCD after MV showed: sensitivity 63.4%, specificity 83.3%, PPV 93%, NPV 39.4% and accuracy 67.9%. The accuracy of TTE and TEE improved when they were compared with c-TCD at rest. CONCLUSIONS TTE and TEE show a considerable number of false negatives for RLS detection. Clinical studies should consider the c-TCD as the best technique to diagnose RLS when a paradoxical embolism is suspected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Comparison of agitated saline mixed with blood to agitated saline alone in detecting right-to-left shunt during contrast- transcranial Doppler sonography examination.

PURPOSE To evaluate a technique for contrast agent preparation as mixing the patients' blood with agitated saline and to compare it with agitated saline alone in diagnosis of cardiac right-to-left shunt in regard to their sensitivity, time window, and distribution of artificially induced microembolic signals. METHODS Fifty-two patients with stroke who had Transesophageal echocardiography prov...

متن کامل

Contrast transcranial Doppler compared to transesophageal echocardiography in detection of right-to-left shunt.

OBJECTIVE To assess contrast transcranial Doppler (TCD) for detection of right-to-left shunt (RLSh). METHODS We studied 30 patients aged between 25-45 years admitted to Al-Zahra Hospital, affiliated to Isfahan University of Medical Sciences, between May 2003 and May 2005. All patients underwent transesophageal echocardiography (TEE) with contrast and contrast TCD. RESULTS Eleven (36.6%) pat...

متن کامل

Foramen Ovale in Stroke Patients

Background and Purpose: The prevalence of a patent foramen ovale has been shown to be increased in patients with ischemic stroke. Transesophageal echocardiography, transthoracic echocardiography, and transcranial Doppler examination with contrast injection can all be used to search for a patent foramen ovale. We compared the accuracy of these techniques for identifying a patent foramen ovale in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurologia

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 2012