Experience with the modified Blalock-Taussig operation using polytetrafluoroethylene (Impra) grafts.

نویسندگان

  • P H Kay
  • A Capuani
  • R Franks
  • C Lincoln
چکیده

Between June 1978 and January 1982, 115 patients underwent 122 subclavian artery-pulmonary artery shunts using polytetrafluoroethylene (PTFE Impra) grafts. Forty-six of the patients had a ductus dependent pulmonary circulation, the patency of which was maintained by an infusion of prostaglandin E2 in 29 cases. There were nine hospital deaths, four of which were related to shunt failure. Five patients underwent a second shunt procedure within one week of the first. There were two cases of late graft occlusion. Twelve shunts were considered to have failed. The actuarial estimate of shunt patency was 90% (+/- 3%) at two years for all patients and 74% (+/- 10%) for neonates. There was no statistically significant difference in two year shunt patency between 4 mm grafts (88 +/- 5%) and 6 mm grafts (96 +/- 3%). The modified Blalock shunt using a PTFE graft is an effective pulmonary-systemic shunt with a good short term patency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perigraft seroma complicating the modified Blalock-Taussig shunts: two consecutive instances with review of literature.

Systemic-to-pulmonary artery shunts using polytetrafluoroethylene (PTFE) (modified Blalock-Taussig shunt) are being used successfully in palliation of cyanotic congenital heart diseases. Graft thrombosis is by far the most common complication of the procedure. Persistant serum leakage through PTFE graft causing perigraft seroma is a rare but devastating complication resulting in increased durat...

متن کامل

Blalock - Taussig shunt . modified ( polytetrafluoroethylene ) Balloon dilatation of a stenosed

A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence ofproximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months la...

متن کامل

Infection of modified Blalock shunts.

A left-sided interposition graft (modified Blalock-Taussig anastomosis) was constructed with polytetrafluoroethylene in a three month old child with tetralogy of Fallot. This shunt thrombosed and a replacement shunt became the site of chronic Pseudomonas infection. The second anastomosis was excised and a third interposition graft was inserted on the right side because the anatomy was unsuitabl...

متن کامل

Modified Blalock-taussig Shunt ----in- Hospital Shunt Occlusion: Experience at Nicvd

A modified Blalock-Taussig shunt (mBTS) is a surgically placed graft between the systemic and pulmonary arterial circulations that redirects systemic blood flow into the pulmonary circulation. It is often placed in those with rightsided obstructive cardiac defects to increase pulmonary blood flow. Postoperative shunt patency is critical to adequate systemic oxygenation. Nevertheless, in the imm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 49 4  شماره 

صفحات  -

تاریخ انتشار 1983