Detecting energy dependent neutron capture distributions in a liquid scintillator
نویسندگان
چکیده
A novel technique is being developed to estimate the effective dose of a neutron field based on the distribution of neutron captures in a scintillator. Using Monte Carlo techniques, a number of monoenergetic neutron source energies and locations were modelled and their neutron capture response was recorded. Using back propagation Artificial Neural Networks (ANN) the energy and incident direction of the neutron field was predicted from the distribution of neutron captures within a Li-loaded liquid scintillator. Using this proposed technique, the effective dose of Cf, AmBe and AmLi neutron fields was estimated to within 30% for four perpendicular angles in the horizontal plane. Initial theoretical investigations show that this technique holds some promise for real-time estimation of the effective dose of a neutron field. & 2014 Elsevier B.V. All rights reserved.
منابع مشابه
An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy
Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...
متن کاملA Sequential Least-squares Algorithm for Neutron Spectrum Unfolding from Pulse-height Distributions Measured with Liquid Scintillators
In this paper, we present a neutron spectrum unfolding technique based on a modification of the least-squares method. The main innovation is the use of a Krylov subspace iteration method to solve the least-squares normal equations. This method was employed because it performs better on ill-conditioned systems of linear equations as compared with standard direct-solution methods. Three different...
متن کامل10B Concentration, Phantom Size and Tumor Location Dependent Dose Enhancement and Neutron Spectra in Boron Neutron Capture Therapy
Background: The amount of average dose enhancement in tumor loaded with 10B may vary due to various factors in boron neutron capture therapy.Objective: This study aims to evaluate dose enhancement in tumor loaded with 10B under influence of various factors and investigate the dependence of this dose enhancement on neutron spectra changes.Material and Methods: In this simulation stud...
متن کاملMeasurements of low-energy (d,n) reactions for BNCT. Boron Neutron Capture Therapy.
Neutron yields and energy spectra have been measured for various deuteron-induced reactions at low energy. Neutrons of energy > 100 keV emitted in the 9Be(d,n)10B, 12C(d,n)13N, and 13C(d,n)14N reactions at Ed= 1.5 MeV were detected at five angles by means of liquid scintillator detectors. While low-energy neutrons were observed in all studied reactions, only 13C(d,n)14N is characterized by a re...
متن کاملشبیهسازی تابع پاسخ سوسوزنهای آلی به تابش گاما و نوترون با استفاده از کدهای مونت کارلوی FLUKA،MCNPX و SCINFUL
In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...
متن کامل