Liquid Carbon Reflectivity at 19 nm
نویسندگان
چکیده
We hereby report on a pump-probe reflectivity experiment conducted on amorphous carbon, using a 780 nm laser as a pump and a 19 nm FEL emission as probe. Measurements were performed at 50 degrees with respect to the surface normal to have an un-pumped reflectivity higher than 0.5%. A sub-10 fs time synchronization error could be obtained exploiting the nearly jitter-free capabilities of FERMI. EUV FEL-based experiments open the way to study the behaviour of a liquid carbon phase being unaffected by plasma screening.
منابع مشابه
A Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay
We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...
متن کاملNanosecond time-resolved reflectivity determination of the melting of metals upon pulsed laser annealing
Thin metal fiIrns (Cu, Au, Ni) on quartz glass were illuminated with nanosecond pulse.; of a frequency doubled Nd:YAG laser (A = 532 nm). The transient reflectivity behavlour was probed at the wavelength 633 nm, where these metals exhibit Drude-Iike optical behaviour: the reflectivity decreases with temperature in the solid and in the Iiquid state as well as at the solid-llquid phase transition...
متن کاملReflectivity degradation of grazing-incident EUV mirrors by EUV exposure and carbon contamination
Reflectivity degradation of grazing-incident extreme ultraviolet (EUV) mirror samples by EUV exposure was investigated in a commercial XTS 13-35 EUV source. The roughness of EUV exposed samples increases with an increase in exposure time due to the erosion of sample surface by ions and neutrals, or deposition of contaminant such as carbon on the sample surface. While energetic debris certainly ...
متن کاملCoherent phonon anisotropy in aligned single-walled carbon nanotubes.
By time-resolved reflectivity measurements with sub-10 fs laser pulses at 395 nm, the coherent phonons of aligned bundles of single-walled carbon nanotubes are observed for various polarization directions of the pump and probe pulses. In the isotropic reflectivity measurement, we observe the radial breathing modes, G, and even D modes, while in the anisotropic reflectivity mode, only the G mode...
متن کاملSurface plasmon resonance of gold nanoparticles assemblies at liquid | liquid interfaces.
Surface plasmon resonance (SPR) was observed when a planar close-packed assembly of gold nanoparticles (Au NPs) is adsorbed at the water|1,2-dichloroethane interface. Aqueous gold nanoparticles, 13 or 16 nm in diameter, are deposited at the interface by adding methanol to form a close-packed film with a visible gold mirror reflectance. By total internal reflection of a light beam on the interfa...
متن کامل