Pitch discrimination of patterned electric stimulation.

نویسندگان

  • Hongbin Chen
  • Yumi Christine Ishihara
  • Fan-Gang Zeng
چکیده

One reason for the poor pitch performance in current cochlear-implant users may be the highly synchronized neural firing in electric hearing that lacks stochastic properties of neural firing in normal acoustic hearing. This study used three different electric stimulation patterns, jittered, probabilistic, and auditory-model-generated pulses, to mimic some aspects of the normal neural firing pattern in acoustic hearing. Pitch discrimination was measured at standard frequencies of 100, 250, 500, and 1000 Hz on three Nucleus-24 cochlear-implant users. To test the utility of the autocorrelation pitch perception model in electric hearing, one, two, and four electrodes were stimulated independently with the same patterned electric stimulation. Results showed no improvement in performance with any experimental pattern compared to the fixed-rate control. Pitch discrimination was actually worsened with the jittered pattern at low frequencies (125 and 250 Hz) than that of the control, suggesting that externally introduced stochastic properties do not improve pitch perception in electric stimulation. The multiple-electrode stimulation did not improve performance but did not degrade performance either. The present results suggest that both "the right time and the right place" may be needed to restore normal pitch perception in cochlear-implant users.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined electric and acoustic hearing performance with Zebra® speech processor: speech reception, place, and temporal coding evaluation.

OBJECTIVE To assess the auditory performance of Digisonic(®) cochlear implant users with electric stimulation (ES) and electro-acoustic stimulation (EAS) with special attention to the processing of low-frequency temporal fine structure. METHOD Six patients implanted with a Digisonic(®) SP implant and showing low-frequency residual hearing were fitted with the Zebra(®) speech processor providi...

متن کامل

Abnormal Pitch Perception Produced by Cochlear Implant Stimulation

Contemporary cochlear implants with multiple electrode stimulation can produce good speech perception but poor music perception. Hindered by the lack of a gold standard to quantify electric pitch, relatively little is known about the nature and extent of the electric pitch abnormalities and their impact on cochlear implant performance. Here we overcame this obstacle by comparing acoustic and el...

متن کامل

Non-Invasive Brain Stimulation Applied to Heschl's Gyrus Modulates Pitch Discrimination

The neural basis of the human brain's ability to discriminate pitch has been investigated by functional neuroimaging and the study of lesioned brains, indicating the critical importance of right and left Heschl's gyrus (HG) in pitch perception. Nonetheless, there remains some uncertainty with regard to localization and lateralization of pitch discrimination, partly because neuroimaging results ...

متن کامل

Music and Pitch Perception of Cochlear Implant Recipients

Users of cochlear implants (CIs) often achieve good performance in speech recognition, but report that music sounds unnatural and is often unrecognisable. This thesis reports experiments to determine the relationship between the perception by CI users of parameters related to music (and to tonal languages) and the parameters of the signals that give rise to them. For electrical stimulation by p...

متن کامل

Temporal pitch in electric hearing.

Both place and temporal codes in the peripheral auditory system contain pitch information, however, their actual use by the brain is unclear. Here pitch data are reported from users of the cochlear implant, which provides the ability to change the temporal code independently from the place code. With fixed electrode stimulation, both frequency discrimination and pitch estimate data show that th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 118 1  شماره 

صفحات  -

تاریخ انتشار 2005