Effect of needle size on success of transarterial axillary block.
نویسندگان
چکیده
The transarterial approach to brachial plexus block is a well-established method of producing anesthesia of the upper extremity. However, it is associated with a failure rate of 20% to 30%. Failure may be secondary to the common use of a relatively long needle, which can penetrate the posterior wall of the sheath and result in inadvertent injection of the local anesthetic into the surrounding tissue. The purpose of this investigation was to compare success rates following transarterial brachial plexus block with a standard 22-gauge, 1 1/2-in, B bevel needle or a 26-gauge, 1/2-in needle. We enrolled 98 subjects scheduled for elective surgery at or below the elbow and randomized them into 2 groups. The control group received a transarterial axillary block with a standard 22-gauge, 1 1/2-in, B bevel needle, and the experimental group received a transarterial axillary block with a 26-gauge, 1/2-in needle. Success was defined as no discomfort at the time of incision. Success rates were compared using a chi 2 test, and a P value of less than .05 was considered significant. The overall success rate was significantly higher with the 26-gauge, 1/2-in needle (42/48 [88%]) than with the 22-gauge, 1 1/2-in needle (39/49 [69%]; P = .035).
منابع مشابه
Comparison of axillary block techniques: is there a difference in success rates?
This study compared the success rates between two accepted methods of performing axillary blocks, the peripheral nerve stimulator (PNS) and the transarterial (TA) techniques. Success was based on blocking the nerves involved in the surgery. Following institutional review board approval and informed consent, 57 patients between the ages of 18 and 86 years of age scheduled for elective upper extr...
متن کاملبلوک شبکه عصبی براکیال با هدایت اولتراسوند: بررسی 30 مورد
Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes m...
متن کاملClinical and radiological comparison of perivascular and transarterial techniques of axillary brachial plexus block.
The perivascular technique of axillary brachial plexus block results in incomplete block of radial and musculocutaneous nerves in 10-20% of patients. With the transarterial technique and a large dose of mepivacaine, success rates of 99% have been reported. We have compared the clinical efficacy of these techniques in 50 patients using 1% mepivacaine 45 ml with adrenaline. If required, the block...
متن کاملDouble-injection perivascular ultrasound-guided axillary brachial plexus block according to needle positioning: 12 versus 6 o'clock position of the axillary artery
BACKGROUND We conducted prospective, randomized, observer-blinded trial to compare two double-injection perivascular (PV) ultrasound-guided techniques of axillary brachial plexus block (BPB). METHODS American Society of Anesthesiologists physical status I-II, 50 patients undergoing surgery of the forearm, wrist or hand were randomly allocated to two groups. For PV12 group, injection was carri...
متن کاملNon-Stimulation Needle with External Indwelling Cannula for Brachial Plexus Block and Pain Management in 62 Patients Undergoing Upper-Limb Surgery
OBJECTIVE To investigate the feasibility of a non-stimulation needle with an external indwelling cannula for upper-limb surgery and acute postoperative pain management. METHODS 62 patients undergoing either scheduled or emergency upper-limb surgery received brachial plexus block of modified interscalene or axillary brachial and then postoperative patient-controlled analgesia (PCA) with local ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AANA journal
دوره 72 1 شماره
صفحات -
تاریخ انتشار 2004