Comparison of transcutaneous and plasma bilirubin measurement.
نویسندگان
چکیده
OBJECTIVES To compare transcutaneous bilirubin measurements made using Bilicheck equipment with assays of capillary plasma using the Unistat bilirubinometer (Leica). METHODS Two hundred concomitant assays were performed (transcutaneous and in plasma), and the correlation and level of agreement between them was calculated. An assessment was also made of the influence of birth weight, skin color, gestational age, postnatal age and phototherapy. RESULTS The linear correlation coefficient was 0.92, and the mean difference between assays was 0.72 (+/-1.57) mg/dL, with a 95% confidence interval from -2.42 to +3.86. The best of a series of ROC curves demonstrated that transcutaneous assays at 14 mg/dL offer the best sensitivity (88.2%) and specificity (97.8%), with a positive predictive value of 78.9%, negative predictive value of 98.9 and are below the curve of 0.98. CONCLUSIONS Assays performed using Bilicheck can be substituted for capillary plasma assays up to 14 mg/dL. Above this level the device should only be used for screening for patients whose bilirubin should be assayed in blood.
منابع مشابه
A Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates
Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...
متن کاملComparing transcutaneous bilirubin versus serum bilirubin measurement using spectrophotometry for jaundice screening of full-term neonates
Background: Neonatal jaundice is an almost common problem among neonates that may cause complications such as kernicterus in severe cases. Since early diagnosis and proper treatment of neonatal jaundice is vital to prevent the related complications, it is necessary to check bilirubin before discharging the neonates. There are several evaluating and diagnostic methods to measure the level of bil...
متن کاملThe Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran
The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...
متن کاملInfluence of assessment site in measuring transcutaneous bilirubin
OBJECTIVE To investigate the influence of the site of measurement of transcutaneous bilirubin (forehead or sternum) in reproducibility of results as compared to plasma bilirubin. METHODS A cohort study including 58 term newborns with no hemolytic disease. Transcutaneous measurements were performed on the forehead (halfway between the headline and the glabella, from the left toward the right s...
متن کاملApplication of transcutaneous bilirubinometry for screening of neonates with significant hyperbilirubinemia in the city of Kerman
In order to screen for neonatal significant hyperbilirubinemia,a propective cross sectional study was carried out on 343 full-term neonates taken to investigator in Kerman between October 1995 and july 1996.there was a linear correlation between serum bilirubin and transcutaneous bilirubinometri (r=0.85,standard error=0.004).sensitivity and specificity of this method were 95% and 84% respective...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Jornal de pediatria
دوره 83 3 شماره
صفحات -
تاریخ انتشار 2007