Titration procedures for nasal CPAP: Automatic CPAP

نویسندگان

  • Katrien B. Hertegonne
  • Jana Volna
  • Sofie Portier
  • Rebecca De Pauw
  • Georges Van Maele
  • Dirk A. Pevernagie
چکیده

Background: The best method for titration of continuous positive airway pressure (CPAP) therapy in obstructive sleep apnea (OSA) syndrome has not yet been established. The 90th or 95th percentiles of the pressure titrated over time by automatic CPAP (A-CPAP) have been recommended as reference for prescribing therapeutic fixed CPAP (F-CPAP). We compared A-CPAP to F-CPAP, which was determined by a common prediction formula. Methods: Forty-five patients who were habituated to F-CPAP underwent titration polysomnography. In a double-blind, randomized order, each patient used an A-CPAP device in the autotitration and in the fixed pressure mode during one half of the night. Apnea–hypopnea index (AHI) and pressure profiles were primary outcomes. Bias and precision were additionally assessed for both CPAP modes. Results: No significant differences in various sleep parameters or in subjective sleep quality evaluation were found. The AHI was effectively lowered in both CPAP modes (A-CPAP 7.7 [10.8] events/h versus F-CPAP 5.4 [9.0] events/h, p = 0.061). Comparison of group means showed that F-CPAP closely paralleled mean (Pmean) and median (P50), but not the 95th percentile (P95) pressure, of A-CPAP. While bias was lowest for Pmean and P50, there was a lack of precision in all A-CPAP pressure categories. Conclusions: We confirm that F-CPAP set by prediction formula is not worse in terms of AHI control than A-CPAP. On average, F-CPAP parallels Pmean and P50 but not P95. However, due to imprecise matching, individual F-CPAP values cannot be derived from Pmean or P50. 2007 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sleep-related breathing disorders. 5. Nasal continuous positive airway pressure treatment for obstructive sleep apnoea.

CPAP should be considered the first line of treatment in patients with moderate to severe obstructive sleep apnoea. In our centre in Sydney this generally means patients with more than 20 apnoea/hypopnoeas per hour with repeated dips in oxyhaemoglobin saturation and usually some symptomatology. Despite this first line role of nasal CPAP, recent objective studies question whether earlier enthusi...

متن کامل

Unattended home diagnosis and treatment of obstructive sleep apnea without polysomnography.

OBJECTIVE To test the effectiveness of unattended home monitoring along with automatic titrating continuous positive airway pressure (auto-CPAP) as an acceptable method for diagnosing and prescribing proper CPAP pressure for treatment of patients presenting with classic symptoms of obstructive sleep apnea (OSA). DESIGN Nonrandomized, prospective case study of 63 patients with a presumptive di...

متن کامل

درمان زودرس با Nasal CPAP در نوزادان نارس با سندرم دیسترس تنفسی

Background: Respiratory distress syndrome (RDS) is a major cause of mortality among premature neonates. The present study was conducted to find out whether early nasal CPAP therapy could eliminate the need for mechanical ventilation in premature neonates with RDS. Materials and methods: For this clinical trial, premature neonates with RDS during the first 6 hours following the delivery were as...

متن کامل

[Continuous positive airway pressure used by adults with obstructive sleep apneas after prescription in a public referral hospital in Mexico City].

OBJECTIVE The aim of this study was to analyze the frequency of initiation of continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea syndrome (OSAS) in a referral hospital in Mexico City serving mainly patients without public health insurance coverage and to assess their level of adherence. PATIENTS AND METHODS Patients with OSAS diagnosed by polysomnography or by...

متن کامل

Reliability of home CPAP titration with different automatic CPAP devices

BACKGROUND CPAP titration may be completed by automatic apparatus. However, differences in pressure behaviour could interfere with the reliability of pressure recommendations. Our objective was to compare pressure behaviour and effective pressure recommendations between three Automatic CPAP machines (Autoset Spirit, Remstar Auto, GK 420). METHODS Sixteen untreated obstructive sleep apnea pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007