A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: a biomechanical study in a porcine model.

نویسندگان

  • Michael P Walsh
  • Coen A Wijdicks
  • Josh B Parker
  • Onur Hapa
  • Robert F LaPrade
چکیده

BACKGROUND Effective soft tissue graft fixation to the tibial tunnel in all-inside anterior cruciate ligament reconstructions has been reported to be a problem and may lead to retrograde pullout at ultimate load testing. HYPOTHESIS A combined retrograde bioabsorbable screw and cortical-cancellous suture button suspension apparatus would gain stiffness from the button and strength from the screw, thus providing for a larger pullout ultimate load, yield load, and stiffness when compared with either fixation alone in an all-inside anterior cruciate ligament reconstruction. STUDY DESIGN Controlled laboratory study. METHODS Eighteen porcine tibias (average bone mineral density of 1.46, measured by dual-energy x-ray absorptiometry scan) and 18 bovine extensor tendon allografts were divided into 3 groups: retrograde bioabsorbable screw fixation, cortical-cancellous suture button suspension apparatus fixation, and combined fixation in the tibia, with 6 specimens per group. They were biomechanically tested with cyclic (500 cycles, 50-250 N, 1 Hz) and load-to-failure (20 mm/min) parameters. RESULTS During cyclic testing, the retrograde screw-only group had a larger cyclic displacement (2.98 +/- 2.28 mm) than the suture button with retrograde screw combination group (1.40 +/- 0.34 mm). The combination fixation group also produced a higher cyclic stiffness (161.93 +/- 61.81 N/mm) than the retrograde screw-only group (91.59 +/- 43.26 N/mm). In load-to-failure testing, the retrograde screw with suture button combination group withstood significantly higher initial failure forces (873.87 +/- 148.74 N) than the retrograde screw-only (558.44 +/- 126.33 N) and suture button-only (121.76 +/- 40.57 N) groups. Additionally, ultimate loads were also significantly higher for the combination group (1027 +/- 157.11 N) than either the retrograde screw group (679.00 +/- 109.44 N) or the suture button group (161.00 +/- 29.27 N). The retrograde screw with suture button combination group showed significantly higher pullout stiffness (152.50 +/- 46.37 N/mm) than either the retrograde screw-only group (78.31 +/- 12.85 N/mm) or the suture button-only group (25.79 +/- 9.30 N/mm). CONCLUSION Soft tissue grafts fixed with a combination of a retrograde screw and a suture button were able to withstand higher initial failure and ultimate failure loads and were also stiffer than grafts fixed with either a retrograde screw or a suture button alone. CLINICAL RELEVANCE These findings may prove useful in providing additional stability when using an all-inside technique in a difficult case, or in a patient with poor bone stock, and may also be useful as an alternative to more commonly used tibial tunnel soft tissue fixation techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Functional Outcome Following Arthroscopic ACL Reconstruction with Rigid Fix: A Retrospective Observational Study

  Background: No uniform consensus exists to decide type of fixation for arthroscopic anterior cruciate ligament reconstruction. Hypothsis: There is similar functional outcome after rigid fix compared to other methods of fixation which has been published. Study design: Retrospective observational study. Methods: A total of 50 patients underwent arthroscopic anterior cruciate ligament reconstruc...

متن کامل

Comparison of Bioabsorbable Suture Anchor Fixation on the Tibial Side for Anterior Cruciate Ligament Reconstruction Using Free Soft Tissue Graft: Experimental Laboratory Study on Porcine Bone

PURPOSE The use of graft tissue fixation using bioabsorbable interference screws (BISs) in anterior cruciate ligament (ACL) reconstruction offers various advantages, but limited pullout strength. Therefore, additional tibial fixation is essential for aggressive rehabilitation. We hypothesized that additional graft tissue fixation using bioabsorbable suture anchors (BSA) would provide sufficient...

متن کامل

Biomechanical comparison of interference screws and combination screw and sheath devices for soft tissue anterior cruciate ligament reconstruction on the tibial side.

BACKGROUND The tibial fixation site has been reported to be the weakest point in anterior cruciate ligament (ACL) reconstructions. Numerous interference screws and combination screw and sheath devices are available for soft tissue fixation, and a biomechanical comparison of these devices is necessary. HYPOTHESIS Combination screw and sheath devices would provide superior soft tissue fixation ...

متن کامل

Biomechanical testing of implant free wedge shaped bone block fixation for bone patellar tendon bone anterior cruciate ligament reconstruction in a bovine model

BACKGROUND The use of an interference fit wedged bone plug to provide fixation in the tibial tunnel when using bone-patellar tendon-bone autograft for anterior cruciate ligament reconstruction offers many theoretic advantages including the potential to offer a more economical and biological alternative to screw fixation. This technique has not been subjected to biomechanical testing. We hypothe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of sports medicine

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 2009