Effect of pupillary dilation on Haigis formula-calculated intraocular lens power measurement by using optical biometry

نویسندگان

  • Bharkbhum Khambhiphant
  • Suganlaya Sasiwilasagorn
  • Nattida Chatbunchachai
  • Krit Pongpirul
چکیده

PURPOSE The purpose of this study was to evaluate the effect of pupillary dilation on the Haigis formula-calculated intraocular lens (IOL) power and ocular biometry measurements by using IOLMaster(®). METHODS A prospective study was performed for biometry measurements of 373 eyes of 192 healthy subjects using the IOLMaster at the outpatient department of King Chulalongkorn Memorial Hospital from February 2013 to July 2013. The axial length (AL), anterior chamber depth (ACD), keratometry (K), and IOL power were measured before and after 1% tropicamide eye drop instillation. The Haigis formula was used in the IOL power calculation with the predicted target to emmetropia. Each parameter was compared by a paired t-test prior to and after pupillary dilation. Bland-Altman plots were also used to determine the agreement between each parameter. RESULTS The mean age of the subjects was 53.74±14.41 years (range 18-93 years). No differences in AL (P=0.03), steepest K (P=0.42), and flattest K (P=0.41) were obtained from the IOLMaster after pupillary dilation. However, ACD and IOL power were significantly different postdilation (P<0.01 and P<0.01, respectively). In ACD and IOL power measurements, the concordance rates were 93.03% and 97.05% within 95% limits of agreement (-0.48 to 0.26 mm and -1.09 to 0.88 D, respectively) in the Bland-Altman plots. CONCLUSION Biometry measurements in the cycloplegic stage should be considered in the IOL formulas that use parameters other than AL and K.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas

BACKGROUND To evaluate how differences in ocular biometry affects the Hoffer Q, Holladay 1, SRK/T, and Haigis intraocular lens power calculation formulae predictions. METHODS This study was performed on 91 eyes of 91 patients who underwent uneventful cataract surgery. Ocular biometry values were measured using the IOL Master 500, and intraocular lens (IOL) power was calculated using the Haigi...

متن کامل

Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

PURPOSE To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). SETTING Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Pa...

متن کامل

Intraocular lens power calculation and optimized constants for highly myopic eyes.

PURPOSE To determine the accuracy of intraocular lens (IOL) power calculations in eyes with high myopia and to suggest adjusted constants for these cases. SETTING Centre for Ophthalmology, Eberhard-Karls-University, Tuebingen, Germany. METHODS Patients with high myopia having phacoemulsification with implantation of an AcrySof MA60MA IOL (power range +5.00 to -5.00 diopters [D]) were evalua...

متن کامل

Effect on refractive outcomes after cataract surgery of intraocular lens constant personalization using the Haigis formula.

PURPOSE To quantify the effect on refractive outcomes after cataract surgery of personalization of Haigis intraocular lens (IOL) constants for a given surgeon-IOL combination. SETTING Institute of Eye Surgery and Institute of Vision Research, Whitfield Clinic, Butlerstown North, Waterford, Ireland. METHODS Personalization of Haigis IOL constants was performed using a series of 248 suitable ...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016