Fidelity of DNA polymerases in DNA amplification.

نویسندگان

  • P Keohavong
  • W G Thilly
چکیده

Denaturing gradient gel electrophoresis (DGGE) was used to separate and isolate the products of DNA amplification by polymerase chain reaction (PCR). The strategy permitted direct enumeration and identification of point mutations created by T4, modified T7, Klenow fragment of polymerase I, and Thermus aquaticus (Taq) DNA polymerases. Incorrectly synthesized sequences were separated from the wild type by DGGE as mutant/wild-type heteroduplexes and the heteroduplex fraction was used to calculate the average error rate (mutations per base duplication). The error rate induced in the 104-base-pair low-temperature melting domain of exon 3 of the human hypoxanthine/guanine phosphoribosyltransferase (HPRT) gene was approximately 3.4 x 10(-5) for modified T7, 1.3 x 10(-4) for Klenow fragment, and 2.1 x 10(-4) for Taq polymerases after a 10(6)-fold amplification. The error rate for T4 DNA polymerase was not more than 3 x 10(-6) error per base duplication. The predominant mutations were sequenced and found to be transitions of G.C to A.T for T4 and modified T7 DNA polymerases, and A.T to G.C for Taq polymerase. Klenow fragment induced both possible transitions and deletions of 2 and 4 base pairs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A hot start alternative for high-fidelity DNA polymerase amplification mediated by quantum dots.

Quantum dots (QDs) are of great interest due to their unique chemical and physical properties. Recently, a hot start (HS) polymerase chain reaction (PCR) amplification performance based on QDs with a high-fidelity Pfu DNA polymerase has been reported. However, whether QDs can trigger HS effects with other high-fidelity or conventional DNA polymerases is yet to be understood. In the present stud...

متن کامل

PCR amplification of minimal gene expression cassette: an alternative, low cost and easy approach to ‘clean DNA’ transformation

We report here an alternative and easy approach to generate sufficient quantity of minimal gene expression cassette (promoter–open reading frame–terminator) DNA by PCR amplification using high fidelity DNA polymerases. Isolating the minimal gene cassette DNA in large quantities by restriction digestion and gel extraction for biolistic-mediated ‘clean DNA’ transformation, is not only a cumbersom...

متن کامل

Error Rate Comparison during Polymerase Chain Reaction by DNA Polymerase

As larger-scale cloning projects become more prevalent, there is an increasing need for comparisons among high fidelity DNA polymerases used for PCR amplification. All polymerases marketed for PCR applications are tested for fidelity properties (i.e., error rate determination) by vendors, and numerous literature reports have addressed PCR enzyme fidelity. Nonetheless, it is often difficult to m...

متن کامل

Derivatives of Bst-like Gss-polymerase with improved processivity and inhibitor tolerance

At the moment, one of the actual trends in medical diagnostics is a development of methods for practical applications such as point-of-care testing, POCT or research tools, for example, whole genome amplification, WGA. All the techniques are based on using of specific DNA polymerases having strand displacement activity, high synthetic processivity, fidelity and, most significantly, tolerance to...

متن کامل

Comparing the Speed and Product Yield of 7 high fidelity DNA Polymerases

Thermococcus kodakaraensis (strain KOD1), previously thought to be a Pyrococcus sp., is a hyperthermophilic archaea isolated from a solfataric hot spring on Kodakara Island, Japan (Atomi 2004). In preliminary studies to characterize the KOD1 DNA polymerase, researchers found that the enzyme had fidelity comparable to Pfu DNA polymerase, but with an extension rate (referred to as speed) 5 times ...

متن کامل

RAPID AMPLIFICATION OF RM-Yplex ASSAY

A multiplex PCR assay consisting of 13 Rapidly Mutating Y STR loci called RM-Yplex was developed. Platinum® Taq DNA polymerase was used to amplify the 13 Y STR loci in a single reaction in approximately 2.5 hours . In order to shorten the process with reliable results, several DNA polymerases were tested with the multiplex. Phusion® Flash High Fidelity and Platinum® Taq DNA polymerases were inv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 86 23  شماره 

صفحات  -

تاریخ انتشار 1989