Chemical shift-induced phase errors in phase-contrast MRI.

نویسندگان

  • Matthew J Middione
  • Daniel B Ennis
چکیده

Phase-contrast magnetic resonance imaging is subject to numerous sources of error, which decrease clinical confidence in the reported measures. This work outlines how stationary perivascular fat can impart a significant chemical shift induced phase-contrast magnetic resonance imaging measurement error using computational simulations, in vitro, and in vivo experiments. This chemical shift error does not subtract in phase difference processing, but can be minimized with proper parameter selection. The chemical shift induced phase errors largely depend on both the receiver bandwidth and the TE. Both theory and an in vivo comparison of the maximum difference in net forward flow between vessels with and without perivascular fat indicated that the effects of chemically shifted perivascular fat are minimized by the use of high bandwidth (814 Hz/px) and an in-phase TE (high BW-TE(IN)). In healthy volunteers (N = 10) high BW-TE(IN) significantly improves intrapatient net forward flow agreement compared with low bandwidth (401 Hz/px) and a mid-phase TE as indicated by significantly decreased measurement biases and limits of agreement for the ascending aorta (1.8 ± 0.5 mL vs. 6.4 ± 2.8 mL, P = 0.01), main pulmonary artery (2.0 ± 0.9 mL vs. 11.9 ± 5.8 mL, P = 0.04), the left pulmonary artery (1.3 ± 0.9 mL vs. 5.4 ± 2.5 mL, P = 0.003), and all vessels (1.7 ± 0.8 mL vs. 7.2 ± 4.4 mL, P = 0.001).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Convex gradient optimization for increased spatiotemporal resolution and improved accuracy in phase contrast MRI

PURPOSE To evaluate convex gradient optimization (CVX) for increased spatiotemporal resolution and improved accuracy for phase-contrast MRI (PC-MRI). METHODS A conventional flow-compensated and flow-encoded (FCFE) PC-MRI sequence was compared with a CVX PC-MRI sequence using numerical simulations, flow phantom experiments, and in vivo experiments. Flow measurements within the ascending aorta,...

متن کامل

Correction of gradient-induced phase errors in radial MRI.

PURPOSE To correct gradient-induced phase errors in radial MRI. METHODS Gradient-induced eddy currents affect the MRI data acquisition by gradient delays and phase errors that may lead to severe image artifacts for non-Cartesian imaging scenarios such as radial trajectories. While gradient delays are dealt with by respective shifts of the acquisition window during radial image acquisition, th...

متن کامل

Reduced chemical shift-induced phase errors at 3T using novel PC-MRI encoding gradients

Background Cardiovascular MRI benefits from improved SNR-efficiency at ≥3T [1,]2, but is subject to other sources of error, which require careful consideration when transitioning from primary use of 1.5T scanners. For example, chemical shift-induced PC-MRI errors [3] are increased at 3T compared to 1.5T. Chemical shift causes the complex perivascular fat signal to chemically shift into the vess...

متن کامل

Delayed phases of contrast MRI, can it be valuable in multiple sclerosis active phase diagnosis?

Background: Observing the enhancing plaques in magnetic resonance imaging (MRI) is one of the most valuable diagnostic modalities in confirming the diagnosis of multiple sclerosis (MS), its recurrence and for better detection of active disease. Since active lesions discovery can improve designating diffusion in time diagnosis of MS and controlling disease activity, and there is not any definite...

متن کامل

Ab Initio Calculation 29Si NMR Chemical Shift Studies on Silicate Species in Aqueous and Gas Phase

Nowadays NMR spectroscopy becomes a powerful tool in chemistry because of the NMR chemical shifts. Hartree–Fock theory and the Gauge-including atomic orbital (GIAO) methods are used in the calculation of 29Si NMR chemical shifts of various silicate species in the silicate solution as initial components for zeolite synthesis both in gas and solution phase. Calculations have been performed at geo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 69 2  شماره 

صفحات  -

تاریخ انتشار 2013