Performance of sodium iodide based (18)F-fluorodeoxyglucose positron emission tomography in the characterization of indeterminate pulmonary nodules or masses.

نویسندگان

  • A G Pitman
  • R J Hicks
  • D S Binns
  • R E Ware
  • V Kalff
  • A F McKenzie
  • D L Ball
  • M P MacManus
چکیده

The purpose of this study was to document the accuracy of (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) with sodium iodide detectors in characterizing indeterminate lung nodules or masses and in identifying additional extra-lesional findings. 50 consecutive patients without a confident diagnosis of malignancy on CT underwent (18)FDG PET with and without attenuation correction. The diagnosis of malignancy was made using visual diagnostic criteria, and tumour-to-blood pool ratios were calculated. The final diagnosis was established by surgery, biopsy or long-term follow-up. Any additional findings made at PET were recorded and similarly verified. Using blinded visual diagnostic criteria for the differentiation of malignant from benign nodules, sodium iodide PET achieved a sensitivity of 91% (30 of 33 cases), a specificity of 88% (15 of 17 cases), a positive predictive value for malignancy of 94% (30 of 32 cases) and a negative predictive value of 83% (15 of 18 cases). False positives occurred with active tuberculosis and sarcoidosis. False negatives were a 3 cm bronchoalveolar carcinoma, a 1.3 cm sarcoma metastasis and a 1 cm carcinoma. Use of tumour-to-blood pool ratios did not improve performance. PET suggested the presence of nodal or distant metastases in 13 of 33 patients with a malignant pulmonary lesion. These PET findings were confirmed in 11 patients. These results indicate that sodium iodide PET is an accurate tool for the characterization of indeterminate pulmonary masses or nodules and simultaneously provides non-invasive staging information that can alter patient management in up to one-third of such patients. Performance of sodium iodide PET is comparable with reported results for PET scanners using other detector materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum: Is fluorine-18 fluorodeoxyglucose positron emission tomography useful for the thyroid nodules with indeterminate fine needle aspiration biopsy? a meta-analysis of the literature

References 1. Wang N, Zhai H, Lu Y: Is fluorine-18 fluorodeoxyglucose positron emission tomography useful for the thyroid nodules with indeterminate fine needle aspiration biopsy? a meta-analysis of the literature. J Otolaryngol Head Neck Surg 2013, 42:38. 2. Vriens D, De Wilt JH, Van der Wilt GJ, Netea-Maier RT, Oyen WJ, De Geus-Oei LF: The role of [18 F]-2-fluoro-2-deoxy-d-glucose-positron em...

متن کامل

18 F-fluoro-deoxy-glucose focal uptake in very small pulmonary nodules: fact or artifact? Case reports

BACKGROUND 18F-fluoro-deoxy-glucose (18 F-FDG) positron emission tomography integrated/combined with computed tomography (PET-CT) provides the best diagnostic results in the metabolic characterization of undetermined solid pulmonary nodules. The diagnostic performance of 18 F-FDG is similar for nodules measuring at least 1 cm and for larger masses, but few data exist for nodules smaller than 1 ...

متن کامل

Dynamic positron emission tomography with F-18 fluorodeoxyglucose imaging in differentiation of benign from malignant lung/mediastinal lesions.

PURPOSE This study was done to evaluate the diagnostic utility of dynamic positron emission tomography (PET) with F-18 fluorodeoxyglucose (FDG) imaging in patients with suspected malignant pulmonary lesions. We wanted to test the hypothesis that the rate of FDG uptake (FDG influx constant values) would differentiate malignant from benign lung or mediastinal lesions. MATERIALS AND METHODS We p...

متن کامل

Dynamic contrast enhanced CT in nodule characterization: How we review and report

Incidental indeterminate solitary pulmonary nodules (SPN) that measure less than 3 cm in size are an increasingly common finding on computed tomography (CT) worldwide. Once identified there are a number of imaging strategies that can be performed to help with nodule characterization. These include interval CT, dynamic contrast enhanced computed tomography (DCE-CT), (18)F-fluorodeoxyglucose posi...

متن کامل

Lung nodule detected by F-18 fluorodeoxyglucose positron emission tomography-computed tomography in patients with papillary thyroid cancer, negative 131I whole body scan, and undetectable serum-stimulated thyroglobulin levels: two case reports

UNLABELLED INTRODUCTION When a pulmonary nodular lesion is detected by F-18 fluorodeoxyglucose positron emission tomography-computed tomography in a patient with post-surgical papillary thyroid carcinoma with undetectable serum-stimulated thyroglobulin levels and negative 131I whole body scan, diagnosis and management of the nodule may be confusing. CASE PRESENTATION We describe two post-s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 75 890  شماره 

صفحات  -

تاریخ انتشار 2002