Systolic ShMOLLI myocardial T1-mapping for improved robustness to partial-volume effects and applications in tachyarrhythmias

نویسندگان

  • Vanessa M. Ferreira
  • Rohan S. Wijesurendra
  • Alexander Liu
  • Andreas Greiser
  • Barbara Casadei
  • Matthew D. Robson
  • Stefan Neubauer
  • Stefan K. Piechnik
چکیده

BACKGROUND T1-mapping using the Shortened Modified Look-Locker Inversion Recovery (ShMOLLI) technique enables non-invasive assessment of important myocardial tissue characteristics. However, tachyarrhythmia may cause mistriggering and inaccurate T1 estimation. We set out to test whether systolic T1-mapping might overcome this, and whether T1 values or data quality would be significantly different compared to conventional diastolic T1-mapping. METHODS Native T1 maps were acquired using ShMOLLI at 1.5 T (Magnetom Avanto, Siemens Healthcare) in 10 healthy volunteers (5 male) in sinus rhythm, at varying prescribed trigger delay (TD) times: 0, 50, 100 and 150 ms (all "systolic"), 340 ms (MOLLI TD 500 ms, the conventional TD for ShMOLLI) and also "end diastolic". T1 maps were also acquired using a shorter readout, to explore the effect of reducing image readout time and sensitivity to systolic motion. The feasibility and image quality of systolic T1-mapping was tested in 15 patients with tachyarrhythmia (n = 13 atrial fibrillation, n = 2 sinus tachycardia; mean HR range 93-121 bpm). RESULTS In healthy volunteers, systolic readout increased the thickness of myocardium compared to the diastolic readout. There was a small overall effect of TD on T1 values (p = 0.04), with slightly shorter T1 values in systole compared to diastole (maximum difference 10 ms). While there were apparent gender differences (with no effect of TD on T1 values in males, more marked differences in females, and exaggeration of this effect in thinner myocardial segments in females), dilatation and erosion of contours suggested that the effect of TD on T1 in females was almost entirely due to more partial-volume effects in diastole. All T1 maps were of excellent quality, but systolic TD and shorter readout were associated with less variability in segmental T1 values. In tachycardic patients, systolic acquisitions produced consistently excellent T1 maps (median R (2) = 0.993). CONCLUSIONS In healthy volunteers, systolic ShMOLLI T1-mapping reduces T1 variability and reports clinically equivalent T1 values to conventional diastolic readout; slightly shorter T1 values in systole are mostly explained by reduced partial-volume effects due to the increase in functional myocardial thickness. In patients with tachyarrhythmia, systolic ShMOLLI T1-mapping is feasible, circumvents mistriggering and produces excellent quality T1 maps. This extends its clinical applicability to challenging rhythms (such as rapid atrial fibrillation) and aids the investigation of thinner myocardial segments. With further validation, systolic T1-mapping may become a new and convenient standard for myocardial T1-mapping.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal variation of magnetic resonance T1 relaxation times in the human population at 1.5 T using ShMOLLI

BACKGROUND Quantitative T1-mapping is rapidly becoming a clinical tool in cardiovascular magnetic resonance (CMR) to objectively distinguish normal from diseased myocardium. The usefulness of any quantitative technique to identify disease lies in its ability to detect significant differences from an established range of normal values. We aimed to assess the variability of myocardial T1 relaxati...

متن کامل

Systolic ShMOLLI T1-mapping is feasible in tachyarrhythmia, with improved image quality compared to diastolic readout

Background T1-mapping using the Shortened Modified Look-Locker Inversion Recovery (ShMOLLI) technique [1] enables assessment of myocardial characteristics, such as oedema, scar and diffuse fibrosis. However, cardiac pathology is often accompanied by tachyarrhythmia, which may cause mistriggering and inaccurate T1 estimation. We hypothesised that systolic T1-mapping may overcome this issue witho...

متن کامل

Comparison of T1 mapping techniques for ECV quantification. Histological validation and reproducibility of ShMOLLI versus multibreath-hold T1 quantification equilibrium contrast CMR

BACKGROUND Myocardial extracellular volume (ECV) is elevated in fibrosis or infiltration and can be quantified by measuring the haematocrit with pre and post contrast T1 at sufficient contrast equilibrium. Equilibrium CMR (EQ-CMR), using a bolus-infusion protocol, has been shown to provide robust measurements of ECV using a multibreath-hold T1 pulse sequence. Newer, faster sequences for T1 mapp...

متن کامل

Standardization of myocardial T1 time measurements in clinical setting using MOLLI, shMOLLI and LL at 1.5T and 3T - the CONSEPT study

Background MMeasurement of myocardial T1 mapping is possible with most of the clinically used magnets using sequences based on modification (MOLLI) or shortening (shMOLLI) of the Look-Locker (LL) sequence. However, the robustness of T1 post-processing approaches has not been systematically examined for these sequences, nor for different field strengths, in native and post-contrast T1 maps. More...

متن کامل

Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold

BACKGROUND T1 mapping allows direct in-vivo quantitation of microscopic changes in the myocardium, providing new diagnostic insights into cardiac disease. Existing methods require long breath holds that are demanding for many cardiac patients. In this work we propose and validate a novel, clinically applicable, pulse sequence for myocardial T1-mapping that is compatible with typical limits for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -