Preoperative scallop-by-scallop assessment of mitral prolapse using 2D-transthoracic echocardiography
نویسندگان
چکیده
BACKGROUND This study was conducted to assess the accuracy of harmonic imaging 2D-transthoracic echocardiography (2D-TTE) segmental analysis compared to surgical findings, in degenerative mitral regurgitation (MR). METHODS Seventy-seven consecutive patients with severe degenerative MR were prospectively enrolled. Preoperative 2D-TTE with precise localization of prolapsing or flailing scallops/segments was performed. All patients underwent mitral valve surgical repair. Surgical reports (SR), including valve description, were used as references for comparisons. A postoperative control 2D-TTE was performed. RESULTS Out of 462 scallops/segments studied, surgical inspection identified 102 prolapses or flails (22%), 92 of which had previously been detected by 2D-TTE (90.2% sensitivity, 100% specificity). Agreement between preoperative 2D-TTE segmental analysis and SR was 97.8% (k = 0.93; p < 0.0001). Sixty-nine out of 77 2D-TTE reports were completely concordant with SR (89.6% diagnostic accuracy). None of the 8 non-concordant 2D-TTE reports were in complete disagreement with SR. P2 scallop was always involved in posterior leaflet prolapse or flail and was described correctly by 2D-TTE in 68 out of 69 patients (98,7% agreement, k = 0,93; 98.5% sensitivity). The anterior leaflet was involved in 14 patients (18%); A2 segment was involved in all of those cases and was correctly detected by 2D-TTE in 13 (98,7% agreement, k = 0,95; 92,8% sensitivity). Antero-lateral and postero-medial para-commissural prolapse or flail had a lower prevalence (14% and 10% respectively), with 2D-TTE sensitivity respectively of 64% and 50%. CONCLUSIONS 2D-TTE, performed by an experienced echo-lab, has very good diagnostic accuracy in localizing the scallops/segments involved in degenerative MR, particularly for the middle ones (P2-A2), which represent almost the totality of prolapses. More invasive, time consuming and expensive exams should be reserved to selected cases.
منابع مشابه
Comparison of real time two-dimensional with live/real time three-dimensional transesophageal echocardiography in the evaluation of mitral valve prolapse and chordae rupture.
We compared live/real time three-dimensional transesophageal echocardiography (3D TEE) with real time two-dimensional transesophageal echocardiography (2D TEE) in the assessment of individual mitral valve (MV) segment/scallop prolapse and associated chordae rupture in 18 adult patients with a flail MV undergoing surgery for mitral regurgitation. 2D TEE was able to diagnose the prolapsing segmen...
متن کاملin the Evaluation of Mitral Valve Prolapse
we studied 49 consecutive patients in whom the sites of mitral valve prolapse were confirmed at the time of operation. The study group consisted of 22 patients with anterior leaflet prolapse, 24 patients with posterior leaflet prolapse, and three patients with multiple scallop prolapse (one patient with both anterior leaflet and middle scallop prolapse, and two patients with both medial and lat...
متن کاملUsefulness of live/real time three-dimensional transthoracic echocardiography in the identification of individual segment/scallop prolapse of the mitral valve.
In this report, we present 34 patients in whom surgical intervention was undertaken for severe mitral insufficiency due to mitral valve prolapse (MVP). Location and severity of MVP and regurgitation were assessed preoperatively by live/real time three-dimensional transthoracic echocardiography and closely agreed with the surgical findings.
متن کاملRole of real-time three-dimensional transesophageal echocardiography in mitral valve repair
Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair. Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy, RT-3D TEE could increase the understanding of MV apparatus and individual scallop identification. We aimed to investigate the value of RT3DTEE in MV repair....
متن کاملHead-to-head comparison of two- and three-dimensional transthoracic and transesophageal echocardiography in the localization of mitral valve prolapse.
OBJECTIVES The aim of this study, undertaken in patients who underwent mitral valve (MV) repair surgery, was to evaluate the feasibility and accuracy of 3-dimensional (3D) transthoracic (TTE) and transesophageal (TEE) echocardiography in the evaluation of MV pathology. BACKGROUND A pre-operative assessment of MV anatomy is essential to surgical design in patients undergoing MV repair. Althoug...
متن کامل