Adaptive-window indicator kriging: A thresholding method for computed tomography images of porous media
نویسندگان
چکیده
Image segmentation is a crucial step in understanding the structure of porous materials, subsequent analyses being profoundly dependent upon segmentation accuracy. Computed tomography images of naturally occurring heterogeneous materials such as soils are particularly challenging to segment reliably, due to the prevalence of partial volume effects, noise, and other artefacts induced during the image acquisition process. As a result, boundaries between classes of objects, typically pore versus solid in the case of soil, are difficult to identify. Indicator kriging can address these problems in a robust fashion but the computational cost can be very great under some circumstances; this is particularly true under conditions that occur regularly in images of soil. The kriging window size parameter is decisive in obtaining a good quality result at reasonable cost, but is difficult to estimate for an image exhibiting significant heterogeneity. This work demonstrates that, allowing the kriging window size to adapt locally throughout the image provides a very efficient solution. Moreover, it is shown that this can be achieved using a conceptually simple mechanism that involves negligible extra processing cost. The adaptive-window indicator kriging method described in this study achieves easily an order of magnitude improvement in computational performance over a fixed size window implementation without sacrificing quality. In addition, it is shown that, by improving the locality of estimation, the new method is robust when applied to soil images. & 2012 Elsevier Ltd. All rights reserved.
منابع مشابه
Segmentation of X-ray computed tomography images of porous materials: A crucial step for characterization and quantitative analysis of pore structures
[1] Nondestructive imaging methods such as X-ray computed tomography (CT) yield high-resolution, three-dimensional representations of pore space and fluid distribution within porous materials. Steadily increasing computational capabilities and easier access to X-ray CT facilities have contributed to a recent surge in microporous media research with objectives ranging from theoretical aspects of...
متن کاملMetal Artifact Reduction of Dental Fillings in Head and Neck CT Images
Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...
متن کاملAbsolute Permeability Calculation by Direct Numerical Simulation in Porous Media
Simulating fluid flow at micro level is an ongoing problem. Simplified macroscopic flow models like Darcy’s law is unable to estimate fluid dynamic properties of porous media. The digital sample reconstruction by high resolution X-ray computed tomography scanning and fluid-dynamics simulation, together with the increasing power of super-computers, allow to carry out pore-scale simulations throu...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملIris localization by means of adaptive thresholding and Circular Hough Transform
In this paper, a new iris localization method for mobile devices is presented. Our system uses both intensity and saturation threshold on the captured eye images to determine iris boundary and sclera area, respectively. Estimated iris boundary pixels which have been placed outside the sclera will be removed. The remaining pixels are mainly the boundary of iris inside the sclera. Then, circular ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computers & Geosciences
دوره 54 شماره
صفحات -
تاریخ انتشار 2013