High resolution ultra-fast sparse sampling with iterative reconstruction imaging for left ventricular evaluation: clinical comparison with standard SSFP imaging
نویسندگان
چکیده
Background Cardiovascular MRI (CMR) has the advantages of high temporal and spatial resolution with excellent endocardial definition, but ECG-gated cine SSFP imaging requires multiple sequential breath-holds and is time-consuming. Sparse sampling with iterative reconstructionallows for ultra-fast acquisitions of SSFP cine images. The accuracy of this technique compared to standard SSFP imaging requires further validation in the clinical setting.
منابع مشابه
Accuracy and feasibility of a free-breathing cine technique sparsely sampled with iterative reconstruction for rapid evaluation of left ventricular function in adults and children
Background Despite being the gold standard for left ventricular function evaluation, traditional SSFP sequences still require multiple breath-holds and a relatively long scan time. This extends total duration of the exam, especially in children or adults with impaired cardiopulmonary capacity. We sought to compare a technique employing a prototype sparse sampling with iterative reconstruction (...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملReal-time magnetic resonance cine imaging with sparse sampling and iterative reconstruction for ventricular measures: comparison with gold-standard segmented steady-state free precession
Background Segmented cine imaging with a steady-state free precession sequence (CINE-SSFP) is currently the gold standard technique for measuring ventricular volumes and mass. It requires multiple breath-holds to cover the entire ventricles, thus being prone to misalignment of consecutive slices, time consuming and dependent on breath-hold (BH) capability. Real-time cine avoids those limitation...
متن کاملFree-breathing real-time cardiac cine MR for evaluation of left-ventricular function: Comparison to standard multi-breath-hold cardiac cine MR in 50 patients
Background Electrocardiogram (ECG)-gated breath-hold cardiac cine magnetic resonance imaging (MRI) is generally accepted as the gold standard for left-ventricular (LV) volume assessment. However, it may fail in patients with arrhythmia, impaired breath-hold capacity, and poor ECG gating. Recently, sparse real-time (RT) cine using a prototype sequence with sparse sampling and iterative reconstru...
متن کاملSingle breath-hold real-time MR cardiac cine for evaluation of left ventricular function
Background Magnetic Resonance (MR) cardiac cine is generally accepted as the gold standard for left ventricular (LV) volume assessment. Recently, Real-Time (RT) cine with sparse sampling technique and iterative reconstruction has been applied to accelerate cine MR. However, in prospective electrocardiogram (ECG) triggered RT cine MR, it may be difficult to capture the true end diastole phase be...