The ultrasonographic deep sulcus sign in traumatic pneumothorax.

نویسندگان

  • Gino Soldati
  • Americo Testa
  • Giulia Pignataro
  • Grazia Portale
  • Daniele G Biasucci
  • Antonio Leone
  • Nicolò Gentiloni Silveri
چکیده

A series of 186 patients with blunt chest trauma was studied with transthoracic ultrasonography to diagnose pneumothorax and to evaluate its size and location. The results were compared with bedside chest radiography and spiral CT scan. The prevalence of pneumothorax on CT scan was 56/186 (30.1%). Pneumothorax was proven on radiography in 30/56 cases without false positive results: "radiographic deep sulcus sign" was evident in 3/29 cases, 26/29 cases being occult. The ultrasound study demonstrated the presence of pneumothorax in 55/56 patients: one occult pneumothorax was missed and no false positive results were observed. The CT scan differed of +/-2.3 cm (range 1-5 cm) from the US study in evaluating size and location of pneumothorax. In conclusion, ultrasound study may detect occult pneumothorax undiagnosed by standard plain radiography. It reflects accurately the extent of pneumothorax if compared with CT scan, outlining the "ultrasonographic deep sulcus sign" on anterior chest wall.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pneumothorax and deep sulcus sign.

A 93-year-old woman who had been a pedestrian was brought to the emergency department after a road traffic accident. On arrival, the patient was conscious and hemodynamically stable with a respiratory rate of 14 breaths/min, pulse rate of 81 beats/min, blood pressure of 141/46 mmHg. The physical examination revealed multiple limb injuries in addition to tenderness on palpation of the right ches...

متن کامل

Ultrasonographic Triangular Cord Sign and Gallbladder Abnormality in Diagnosis of Biliary Atresia

Introduction: Early diagnosis of biliary atresia is very important for better outcome of treatment. Ultrasonography is one of the diagnostic tools for early differentiation of  biliary atresia from other causes of neonatal cholestasis. It has been reported that triangular cord sign  (TACS) in sonography is a reliable sign for diagnosis of biliary atresia. The aim of this study was to re-assess ...

متن کامل

How Accurate Is Ultrasonography for Excluding Pneumothorax? - PIIS0196064412011766

The authors initially identified 570 potential studies but excluded 549 because they were retrospective, editorials, letters, or non-English or because they did not specifically reference ultrasonography or pneumothorax. The remaining 21 studies were reviewed in detail with a standardized data extraction form, resulting in the exclusion of an additional 13, leaving 8 studies for the final analy...

متن کامل

A physiological sign that mimics lung point in critical care ultrasonography

Figure 1 Real-time mode ultrasonography and computed tomography. (a) Real-time mode showed intermittent eradication of cardiac pulse (CP) by the moving lung with respiration cycle. (b) Subsequent computed tomography ruled out pneumothorax. Ultrasound has been widely used in the critical care setting for timely and accurate diagnosis of life-threatening conditions. Pneumothorax is one such condi...

متن کامل

A deceptive pneumothorax.

A 45-year-old male former smoker was admitted after receiving bullet wounds to the head and abdomen. On admission, his Glasgow scale score was 3. The patient required immediate intubation in the emergency room, and following emergency laparotomy he was transferred to the intensive care unit (ICU) for respiratory support. Chest computed tomography (CT) did not reveal any signs of chest injury bu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 32 8  شماره 

صفحات  -

تاریخ انتشار 2006