Radiometric Processing and Calibration of Eo-1 Advanced Land Imager Data

نویسنده

  • B. L. Markham
چکیده

A radiometric and geometric processing system has been developed as part of the Advanced Land Image(r) Assessment System (ALIAS). A derivative of the ALIAS processing system has also been implemented operationally at EROS to generate Advanced Land Imager (ALI) Level 1 radiometrically and geometrically corrected data products. This system replaces the “calibration pipeline” previously used to generate Level 1R radiometrically corrected ALI data products at EROS. The revised calibration systems initially use the same radiometric calibration coefficients as previous systems, i.e., a fixed set of detector-by-detector gains established shortly after launch and biases measured shortly after each scene acquisition by closing the ALI’s shutter. The data are scaled differently in the final products, however. The original calibration pipeline scaled the Level 1R data output by a fixed factor of 300, i.e., to obtain the radiance in mW/cm sr m for a given pixel in any band, you divided the quantized calibrated data value by 300. To scale to W/m sr m, a factor of 30 is used. The revised system uses a band specific multiplicative scaling factor of between 22 and 1100 as well as a band specific additive scaling factor for units of W/m sr m. The band specific multiplicative scaling factor results in better preservation of the ALI’s precision and dynamic range in going from raw to calibrated data, especially in the SWIR bands. This reduces the amount of high signal data being clipped by the rescaling process and reported as saturated in the calibrated data products. Setting the minimum valid data value to “1” DN in the output products combined with the additive factor results in all the valid data being positive values with negligible, if any, loss of valid data. Additional Pecora 16 “Global Priorities in Land Remote Sensing” October 23-27, 2005 * Sioux Falls, South Dakota work is underway to replace the current fixed set of detector gains with time-dependent functions that represent the gradual change in gain of the ALI detectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiometric Calibration Pipeline for the EO-1 Advanced Land Imager

This paper covers the design and initial performance analysis of the radiometric calibration pipeline software for the EO-1 Advanced Land Imager (EO-1). The design and implementation of the software and of the radiometric calibration database are discussed. Radiometric calibration data were gathered in the laboratory during integration and test and were used for initializing the database. This ...

متن کامل

Spectral and Radiometric calibration of the Advanced Land Imager

Calibration of spectral and radiometric measurements of the Advanced Land Imager (ALI) is a critical element of its land-sensing mission. Without initial ground-based and subsequent on-orbit standardization, the data cannot be reliably used for the intricate analysis of atmospheric conditions and complex surface regions. Daily, weekly, and monthly recertification steps are taken to recalibrate ...

متن کامل

Radiometric Characterization and Performance Assessment of the Ali Using Bulk Trended Data

The Earth Observing-1 (EO-1) Advanced Land Imager (ALI), developed as part of NASA’s New Millennium Program, utilizes advances in imaging technologies and techniques to provide high-quality image data compatible with that produced from currently available Landsat Thematic Mapper (TM) technology. As opposed to the Landsat 7 Enhanced Thematic Mapper Plus (ETM+) focal plane design that uses 136 de...

متن کامل

Landsat-8 Operational Land Imager (OLI) Radiometric Performance On-Orbit

Expectations of the Operational Land Imager (OLI) radiometric performance onboard Landsat-8 have been met or exceeded. The calibration activities that occurred prior to launch provided calibration parameters that enabled ground processing to produce imagery that met most requirements when data were transmitted to the ground. Since launch, calibration updates have improved the image quality even...

متن کامل

Vicarious radiometric calibration of EO-1 sensors by reference to high-reflectance ground targets

The Remote Sensing Group at the University of Arizona has been using ground targets for the in-flight vicarious calibration of airborne and satellite sensors since the early 1980s. Targets such as Railroad Valley Playa in north central Nevada and White Sands Missile Range in New Mexico have proven to be useful for this work. This paper presents the results from multiple vicarious calibration ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005