Calibration of reverberation chamber for wireless measurements: Study of accuracy and characterization of the number of independent samples

نویسندگان

  • ELENA MARIA PUCCI
  • Elena Maria Pucci
  • Maria Pucci
چکیده

Traditionally, the Reverberation Chamber (RC) has been used for EMC testing, but recently it has been developed for measuring antennas and mobile terminals designed for wireless applications. It is a metal cavity, large in terms of wavelength which supports several cavity modes at the operation frequency. The modes are stirred by appropriate stirring methods producing a rich scattering environment with Rayleigh distribution of the received complex signal amplitude. Due to the statistical nature of the electromagnetic field inside the chamber, the RC is ideal for simulating in compact space the behavior of mobile terminals operating in fading environments as the urban and the indoor ones. The rapidly growing use of the RC for these kinds of applications has developed the necessity of fast and accurate measurements. In addition, the accuracy is typically more critical in antenna efficiency measurements than in EMC tests. Therefore, studies of the mechanisms that may affect the measurements accuracy are becoming of great interest. If the stirrers are able to perform a proper stirring of the excited modes, a large number of independent field samples are created. The independency of those samples is of great importance in quantifying the uncertainty of a test performed in the cavity. This thesis determines the importance of different steps in the procedure of calibrating a RC in order to improve the accuracy for wireless measurements. The study is performed using the Bluetest High Performance RC at Chalmers University of Technology. By measuring with several stirring configurations, number of stirrer positions and chamber loading, we are able to show how the number of independent samples varies when different stirring techniques are used and extra lossy objects are present inside the chamber. In addition, a new theoretical formula for the estimation of the number of independent samples when different stirring methods are applied is proposed. The results show that the number of independent samples estimated with the new formula and the one measured have a poor agreement at the lower frequencies compared to high fre-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...

متن کامل

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل

تحلیل آکوستیکی یک اتاق نیمه صامت با چینش متقاطع جاذب الیافی مکعب مستطیل

Introduction: The previous studies have used fibrous absorbents usually in the form of cone-shaped wedges for making anechoic and semi-anechoic chambers which their design and construction have been costly and difficult. The present study aimed to design a semi-anechoic chamber, using rectangular fibrous absorbents and also perform acoustic analysis for it. . Material and Method: In the presen...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Diode calibration for dose determination in total body irradiation

Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008