Follow-up results of transvenous occlusion of patent ductus arteriosus with the buttoned device.
نویسندگان
چکیده
OBJECTIVES The purpose of this presentation is to document results of buttoned device (BD) occlusion of patent ductus arteriosus (PDA) in a large number of patients with particular emphasis on long-term follow-up in an attempt to provide evidence for feasibility, safety and effectiveness of this method of PDA closure. BACKGROUND Immediate and short-term results of BD occlusion of PDA have been documented in a limited number of children. METHODS During a six-year period ending August 1996, transcatheter BD closure of PDA was attempted in 284 patients, ages 0.3 to 92 years (median 7) under a protocol approved by the local institutional review boards and FDA with an investigational device exemption in U.S. cases. RESULTS The PDAs measured 1 to 15 mm (median 4) at the narrowest diameter; 20 were larger than 8 mm and 10 larger than 10 mm. They were occluded with devices measuring from 15 to 35 mm delivered via 7F (N = 140) or 8F (N = 144) sheaths. Successful implantation of the device was accomplished in 278 (98%) of 284 patients. The Qp:Qs decreased from 1.8+/-0.6 (mean+/-SD) to 1.09+/-0.19 (p < 0.001). Effective occlusion defined as no (N = 167 [60%]) or trivial (N = 79 [28%]) residual shunt was achieved in 246 (88%) patients. All types of PDAs, irrespective of the shape (conical, tubular or short), size (small or large) or length (short or long) of the PDA and previously implanted Rashkind devices, could be occluded. Follow-up data, 1 to 60 months (median 24) after device implantation, were available in 234 (84%) patients. Seven (3%) patients required reintervention to treat residual shunt with (N = 2) or without (N = 5) hemolysis. Actuarial reintervention-free rates were 95% at 1 and 5 years. There was gradual reduction of actuarial residual shunts and were 40%, 28%, 21%, 14%, 11%, 10%, 6% and 0% respectively at 1 day, 1, 6, 12, 24, 36, 48 and 60 months after device implantation. Incorporation of folding plug over the button loop in 10 additional patients produced immediate and complete occlusion of PDA. CONCLUSIONS This large multiinstitutional experience confirms the feasibility, safety and effectiveness of buttoned device closure of PDAs. All types of PDAs irrespective of the shape, length and diameter can be effectively occluded. Incorporation of folding plug over the button loop produces complete PDA occlusion at the time of device implantation.
منابع مشابه
Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device. Initial clinical experience.
BACKGROUND Several devices are available for transcatheter occlusion of patent ductus arteriosus. Most of these devices either require complicated intracardiac maneuvering, have not been tried in humans, or need a large-sized sheath for implantation of the device. METHODS AND RESULTS During a 26-month period ending November 1992, 14 patients underwent transcatheter closure of patent ductus ar...
متن کامل[Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder: initial results and mid-term follow-up].
INTRODUCTION AND OBJECTIVES Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and mid-term results of the treatment of PDA with the Amplatzer duct occluder. PATIENTS AND METHODS From October 1999 to December 2001, 30 children underwent transcatheter closure of persistent ductus arteriosus at a mean SD age of 5 4....
متن کاملMedium-term follow up of residual shunting and potential complications after transcatheter occlusion of the ductus arteriosus.
OBJECTIVES To determine the causes and outcome of residual shunting after transcatheter occlusion of persistent ductus arteriosus with the Rashkind double umbrella occluder, and to determine the potential of the device to produce obstruction to flow in the aorta and left pulmonary artery. DESIGN Angiographic examination of morphology of ductus followed by prospective clinical and ultrasound e...
متن کاملTranscatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder: Initial Results and Mid-Term Follow-Up
Received 11 March 2002. Accepted for publication 28 May 2002. Introduction and objectives. Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and midterm results of the treatment of PDA with the Amplatzer duct occluder. Patients and methods. From October 1999 to December 2001, 30 children underwent transcatheter clo...
متن کاملDoes change in serum cholesterol of a population influence coronary heart disease mortality?
[1] Shim D, Fedderly RT, Beekman III RH, Ludomirsky A, Young ML, Schork MA, Lloyd TR. Follow-up of coil occlusion of patent ductus arteriosus. J Am Coll Cardiol 1996; 28. 207-11. [2] Galal O, de Moor M, Fadley F et al. Problems encountered during introduction of Gianturco coils for transcatheter occlusion of the patent arterial duct. Eur Heart J 1997; 18: 625-30. [3] Sommer RJ, Gutierrez A, Lai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 33 3 شماره
صفحات -
تاریخ انتشار 1999