Frosted jones pyrex tubes.

نویسندگان

  • Roger A Dailey
  • Robert N Tower
چکیده

PURPOSE To describe the use of a new, frosted Jones Pyrex tube in the treatment of obstructed canaliculi of the upper lacrimal system. The frosted Jones tube retains the advantages of the traditional smooth Pyrex tube yet appears to improve the positional stability in the surgically created fistula. METHODS Ten patients of a single surgeon who had previously undergone external conjunctivodacryocystorhinostomy and placement of a Jones Pyrex tube, with subsequent Pyrex tube extrusion, were included in the study. All had previous success with Pyrex tubes, with follow-up ranging from 1 month to 14 years. In each case, when the patient presented with an extruded tube, it was replaced with a frosted Jones tube (Weiss Scientific Glass Blowing Company, Portland, OR, U.S.A.). RESULTS In this preliminary study, none of the 10 patients fitted with a frosted Jones Pyrex tube had a recurrence of extrusion. All patients reported proper functioning of the tubes, with no complaints of epiphora or discomfort. CONCLUSIONS Compared with a standard Jones Pyrex tube, a frosted tube functions equally well and reduces the possibility of extrusion, which is the main complication of traditional conjunctivodacryocystorhinostomy. We have exchanged smooth tubes for frosted tubes in patients who have had extrusion of the original tube, and we are currently investigating primary placement of the frosted Jones Pyrex tube.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A filter of pyrex glass and stainless steel for use with Seitz filter-pads.

WE have designed a holder for use with Seitz EK bacterial filter-pads (diameter 3 cm.) in which the filtering liquids come in contact only with pyrex glass and a disc of stainless steel. This apparatus has the advantage that toxic metals (e.g. copper) cannot be dissolved by the filtering liquids as from the ordinary metal holder from which the plating (e.g. silver or rhodium) has been worn. Als...

متن کامل

An Exact Solution to Steady Heat Conduction in a Two-Dimensional Annulus on a One-Dimensional Fin: Application to Frosted Heat Exchangers With Round Tubes

The fin efficiency of a high-thermal-conductivity substrate coated with a low-thermalconductivity layer is considered, and an analytical solution is presented and compared to alternative approaches for calculating fin efficiency. This model is appropriate for frost formation on a round-tube-and-fin metallic heat exchanger, and the problem can be cast as conduction in a composite two-dimensional...

متن کامل

Habitat characteristics of adult frosted elfins (Callophrys irus) in sandplain communities of southeastern Massachusetts, USA

Changes to land use and disturbance frequency threaten disturbance-dependent Lepidoptera within sandplain habitats of the northeastern United States. The frosted elfin (Callophrys irus) is a rare and declining monophagous butterfly that is found in xeric open habitats maintained by disturbance. We surveyed potential habitat for adult frosted elfins at four sites containing frosted elfin populat...

متن کامل

Dr. Karl Landsteiner Nobel Prize Laureate in Medicine, 1930.

Dr. Karl Landsteiner-Nobel Prize Laureate in Special Articles: Medicine, 1930: PROFESSOR STANHOPE BAYNEThe Leakage of Helium, through Pyrex Glass at JONES .. 599 Room Temperature, II: PROPESSOR G. P. BAxTER Obituary: and DR. H. W. STARKWEATHER. Increasing the Louis Hermann Panmel: PROPESSOR A. T. ERWIN. Vitamin D Potency of Cow's Milk by the Daily Memorials; Becent Deaths .604 Feeding of Irradi...

متن کامل

Frosted branch angiitis associated with Harada disease-like manifestations recurs 10 years later.

PURPOSE To describe a case with frosted branch angiitis occurring in association with manifestations of Harada disease. CASE A 41-year-old man developed marked iridocyclitis, frosted branch angiitis and retinal white dots, together with serous detachment of the sensory retina in the posterior pole of both eyes. OBSERVATIONS Fluorescein angiography demonstrated multiple retinal pigment epith...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic plastic and reconstructive surgery

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2005