Limited-projection-angle hybrid fluorescence molecular tomography of multiple molecules.

نویسندگان

  • Karin Radrich
  • Pouyan Mohajerani
  • Johanna Bussemer
  • Markus Schwaiger
  • Ambros J Beer
  • Vasilis Ntziachristos
چکیده

An advantage of fluorescence methods over other imaging modalities is the ability to concurrently resolve multiple moieties using fluorochromes emitting at different spectral regions. Simultaneous imaging of spectrally separated agents is helpful in interrogating multiple functions or establishing internal controls for accurate measurements. Herein, we investigated multimoiety imaging in the context of a limited-projection-angle hybrid fluorescence molecular tomography (FMT), and x-ray computed tomography implementation and the further registration with positron emission tomography (PET) data. Multichannel FMT systems may image fluorescent probes of varying distribution patterns. Therefore, it is possible that different channels may require different use of priors and regularization parameters. We examined the performance of automatically estimating regularization factors implementing priors, using data-driven regularization specific for limited-projection-angle schemes. We were particularly interested in identifying the implementation variations between hybrid-FMT channels due to probe distribution variation. For this reason, initial validation of the data-driven algorithm on a phantom was followed by imaging different agent distributions in animals, assuming superficial and deep seated activity. We further demonstrate the benefits of combining hybrid FMT with PET to gain multiple readings on the molecular composition of disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reconstruction for Limited-Projection Fluorescence Molecular Tomography Based on a Double-Mesh Strategy

Limited-projection fluorescence molecular tomography (FMT) has short data acquisition time that allows fast resolving of the three-dimensional visualization of fluorophore within small animal in vivo. However, limited-projection FMT reconstruction suffers from severe ill-posedness because only limited projections are used for reconstruction. To alleviate the ill-posedness, a feasible region ext...

متن کامل

Image processing methods for limited angle tomography and sparse angle tomography

The purpose of medical computed tomography (CT) is to generate a three dimensional (3D) model of inner organs based on number of two dimensional (2D) X-ray images taken from different directions around the patient. Clinical CT imaging improves and extends the operational and diagnostic X-ray imaging since it basically adds a new spatial dimension to the data by converting multiple 2D images int...

متن کامل

In-vivo imaging of murine tumors using complete-angle projection fluorescence molecular tomography.

We interrogate the ability of free-space fluorescence tomography to image small animals in vivo using charge-coupled device (CCD) camera measurements over 360-deg noncontact projections. We demonstrate the performance of normalized dual-wavelength measurements that are essential for in-vivo use, as they account for the heterogeneous distribution of photons in tissue. In-vivo imaging is then sho...

متن کامل

Projection Neuron Circuits Resolved Using Correlative Array Tomography

Assessment of three-dimensional morphological structure and synaptic connectivity is essential for a comprehensive understanding of neural processes controlling behavior. Different microscopy approaches have been proposed based on light microcopy (LM), electron microscopy (EM), or a combination of both. Correlative array tomography (CAT) is a technique in which arrays of ultrathin serial sectio...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2014