Induction, maintenance, and reversal of therapeutic hypothermia with an esophageal heat transfer device.
نویسندگان
چکیده
AIM OF THE STUDY To evaluate a novel esophageal heat transfer device for use in inducing, maintaining, and reversing hypothermia. We hypothesized that this device could successfully induce, maintain (within a 1 °C range of goal temperature), and reverse, mild therapeutic hypothermia in a large animal model over a 30-h treatment protocol. METHODS Five female Yorkshire swine, weighing a mean of 65 kg (range 61-70) kg each, were anesthetized with inhalational isoflurane via endotracheal intubation and instrumented. The esophageal device was connected to an external chiller and then placed into the esophagus and connected to wall suction. Reduction to goal temperature was achieved by setting the chiller to cooling mode, and a 24h cooling protocol was completed before rewarming and recovering the animals. Histopathologic analysis was scheduled for 3-14 days after protocol completion. RESULTS Average baseline temperature for the 5 animals was 38.6 °C (range 38.1-39.2 °C). All swine were cooled successfully, with average rate of temperature decrease of 1.3 °C/h (range 1.1-1.9) °C/h. Standard deviation from goal temperature averaged 0.2 °C throughout the steady-state maintenance phase, and no treatment for shivering was necessary during the protocol. Histopathology of esophageal tissue showed no adverse effects from the device. CONCLUSION A new esophageal heat transfer device successfully and safely induced, maintained, and reversed therapeutic hypothermia in large swine. Goal temperature was maintained within a narrow range, and thermogenic shivering did not occur. These findings suggest a useful new modality to induce therapeutic hypothermia.
منابع مشابه
Temperature modulation with an esophageal heat transfer device- a pediatric swine model study
BACKGROUND An increasing number of conditions appear to benefit from control and modulation of temperature, but available techniques to control temperature often have limitations, particularly in smaller patients with high surface to mass ratios. We aimed to evaluate a new method of temperature modulation with an esophageal heat transfer device in a pediatric swine model, hypothesizing that cli...
متن کاملInduction of therapeutic hypothermia via the esophagus: a proof of concept study.
BACKGROUND Induction of hypothermia (a 4 °C decrease from baseline) improves outcomes in adult cardiac arrest and neonatal hypoxic ischemic encephalopathy, and may benefit other conditions as well. Methods used to implement or prevent hypothermia typically require skin contact with blankets or pads or intravascular access with catheter devices. The study was to evaluate the potential to induce ...
متن کاملImpact of Mild Hypothermia on the Recovery of Patients with Acute Stroke
Background and Objective: Hypothermia induction has been proposed to improve the recovery process of stroke in the last two decades. Therefore, the aim of this study was to investigate the effect of mild hypothermia on the recovery of patients with acute stroke. Materials and Methods: This single-blind randomized clinical trial was conducted on 60 patients with acute stroke in 2018 in Hamadan,...
متن کاملAn additional method for the prevention of hypothermia in severely injured trauma patients
We congratulate Perlman et al. [1] for their excellent manuscript offering a comprehensive review of hypothermia in trauma patients and proposing a goaldirected algorithm for warming the severely injured patient that can be directly incorporated into current Advanced Trauma Life Support guidelines. In this well-crafted algorithm, the authors reveal a pragmatic treatment strategy that can be imp...
متن کاملStudy about heat transfer coefficient of water-nanofluid in pulsating heat pipes
Pulsating heat pipe is an efficient heat exchange device which is being used for cooling and heating recovery. In the present work, we made a closed-loop pulsating heat pipe with six U-turns and we used water in our system. Moreover the use of water-Fe3O4 nanofluid was studied with two different filling ratios 40% and 50% and 1% mass concentration. At the end we calculated heat resistance and h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Resuscitation
دوره 84 11 شماره
صفحات -
تاریخ انتشار 2013