Evaluation of a new method for measurement of minute ventilation recovery time.

نویسندگان

  • Christopher W Seymour
  • Jason D Christie
  • Christina A Gaughan
  • Barry D Fuchs
چکیده

PURPOSE To determine if the measurement of minute ventilation recovery time (V (E)RT), a recently proposed predictor of extubation outcome, can be reproduced using a more practical, simpler method. METHODS A case series with convenience sampling was performed in the surgical intensive care unit of a tertiary-care hospital. Nineteen patients were enrolled during weaning from mechanical ventilation, prior to the initial extubation attempt. Within-subject comparisons of V (E)RT were performed, using 2 alternative methods for measuring baseline V (E) and one alternative method for determining the threshold for recovery of V (E) during the final spontaneous breathing trial prior to extubation. Comparison methods for baseline V (E) included an 8-hour average and the last V (E) measurement prior to the spontaneous breathing trial. The alternative threshold for defining recovery of V (E) was 100% of the baseline value (vs 110% in the original method). RESULTS The study subjects were primarily cardiac surgery patients (63%) and were ventilated for a median of 5 days prior to extubation. V (E)RT calculated using the 8-hour average or the last V (E) measurement prior to the spontaneous breathing trial as baseline, and a threshold of 100% of baseline V (E) to define recovery most closely approximated V (E)RT obtained by the original method and similarly classified patients at high risk for reintubation (kappa statistic = 0.78 +/- 0.2). CONCLUSIONS V (E)RT can be determined using a simpler method for measuring both baseline V (E) and the recovery threshold. These methodological modifications may increase the feasibility of measuring V (E)RT, while reproducing the results obtained by the original method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of a baseline minute ventilation for the calculation of minute ventilation recovery time: is a subjective method reliable?

BACKGROUND Minute ventilation recovery time is a new predictor of extubation outcome that uses a subjective method for the determination of baseline minute ventilation (V(E)) during its measurement. The purpose of the current study is to evaluate the inter-rater reliability of this subjective method for determining baseline V(E). METHODS Three critical-care physicians served as independent re...

متن کامل

A new method for determination of frothability of frothers by using water recovery measurement

A new method was introduced for frothing characterization of flotation frothers. Method uses water recovery to develop a new frothability index named water recovery index (WRI). New index was determined for some commercial frothers and results were compared with dynamic frothability index (DFI). Results showed that water recovery index values follow the order of A-65 13016 s/mol > DF-250 6292.4...

متن کامل

Comparison of the Effects of Open and Closed Endotracheal Suction on Cardiovascular and Ventilation Parameters for Patients Undergoing Mechanical Ventilation

Background and Objectives: Suction is a necessary and common method which aids in the release of secretion from the respiratory system for the patients who have undergone mechanical ventilation. One of the most common complications of suction is hypoxemia which causes dysrhythmia and death. The purpose of this study was to determine the effects of open and closed-endotracheal suction on cardiov...

متن کامل

Investigation of oxygenation in premature infants under mechanical ventilation in supine position compare to side lying

Abstract Introduction: Changing position is an important aspect within nursing care. Prone positioning amongst premature infants could improve their oxygenation compared to supine position. Side lying position leads to developed support between premature infants, however there is few studies about effects of this position on premature infants 'oxygenation. Objective: This study was conduc...

متن کامل

The Comparison Effects of Two Methods of (Adaptive Support Ventilation Minute Ventilation: 110% and Adaptive Support Ventilation Minute Ventilation: 120%) on Mechanical Ventilation and Hemodynamic Changes and Length of Being in Recovery in Intensive Care Units

BACKGROUND The conventional method for ventilation is supported by accommodative or adaptive support ventilation (ASV) that the latter method is done with two methods: ASV minute ventilation (mv): 110% and ASV mv: 120%. Regarding these methods this study compared the differences in duration of mechanical ventilation and hemodynamic changes during recovery and length of stay in Intensive Care Un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2006