The "final voyage" of the Endeavor stent.
نویسنده
چکیده
The “final” 5-year outcomes of combined trials with the Endeavor zotarolimus-eluting stent (E-ZES) by Kandzari et al. (1), published in this issue of JACC: Cardiovascular Interventions, might be considered a companion to the Kirtane et al. (2) publication in the issue last month of JACC: Cardiovascular Interventions, which reported on the “final” 5-year follow-up of the ENDEAVOR IV (A Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) study. Both papers represent an opportunity to place the long-term clinical results of the Endeavor stent in perspective for the here-and-now.
منابع مشابه
The "final" 5-year follow-up from the ENDEAVOR IV trial comparing a zotarolimus-eluting stent with a paclitaxel-eluting stent.
OBJECTIVES This study sought to report the final 5-year outcomes of the ENDEAVOR IV (A Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) trial comparing the Endeavor zotarolimus-eluting stent (E-ZES) (Medtronic, Santa Rosa, California) with the T...
متن کاملSubclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis
Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...
متن کاملOptimizing Voyage Plan in way of Persian Gulf and Red Sea Using Meteorology and Oceanography Satellite Data
The weather forecast by satellite data is a good guideline for assessment of voyage planning route in order to have safe and economic voyage for shipping. ISO15016, "Guidelines for the assessment of speed and performance by analysis of speed trial data", has been developed by the working group ISO/TC 8/SC 9/WG 2. This paper presents the effects of wave speed & direction, wind speed and directio...
متن کاملRandomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial.
BACKGROUND The use of the Endeavor stent might reduce restenosis and stent thrombosis at 9 months. METHODS AND RESULTS Patients (n = 1197) treated for single coronary artery stenosis were enrolled in a prospective, randomized, double-blind study and randomly assigned to receive the Endeavor zotarolimus-eluting phosphorylcholine polymer-coated stent (n = 598) or the same bare metal stent but w...
متن کاملImpact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.
BACKGROUND Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS Data were obtained from...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 6 5 شماره
صفحات -
تاریخ انتشار 2013