Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis
نویسندگان
چکیده
Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left ventricle dilatation due to a severe paravalvular leak. Patient was unresponsive to elective balloon post-dilatation, and therefore she was successfully treated with open-heart surgery to remove the malfunctioning CoreValve bioprosthesis and perform standard aortic valve replacement.
منابع مشابه
Matched Comparison of Self-Expanding Transcatheter Heart Valves for the Treatment of Failed Aortic Surgical Bioprosthesis
Background—Transcatheter valve-in-valve implantation is an established therapy for high-risk patients with failed surgical aortic bioprosthesis. There are limited data comparing outcomes of valve-in-valve implantation using different transcatheter heart valves (THV). Methods and Results—Patients included in the Valve-in-Valve International Data registry (VIVID) and treated with selfexpanding TH...
متن کاملTranscatheter bioprosthesis implantation for the treatment of aortic stenosis: three-year experience.
BACKGROUND Transcatheter aortic bioprosthesis implantation is a new treatment modality for patients with aortic stenosis who are inoperable or at high surgical risk. OBJECTIVE To report the three-year experience with transcatheter CoreValve® bioprosthesis implantation. METHODS From January 2008 to January 2011, 35 patients with aortic stenosis (33) or aortic valve bioprosthesis dysfunction ...
متن کاملMatched Comparison of Self-Expanding Transcatheter Heart Valves for the Treatment of Failed Aortic Surgical Bioprosthesis: Insights From the Valve-in-Valve International Data Registry (VIVID).
BACKGROUND Transcatheter valve-in-valve implantation is an established therapy for high-risk patients with failed surgical aortic bioprosthesis. There are limited data comparing outcomes of valve-in-valve implantation using different transcatheter heart valves (THV). METHODS AND RESULTS Patients included in the Valve-in-Valve International Data registry (VIVID) and treated with self-expanding...
متن کاملSelf-expandable transcatheter aortic valve implantation for aortic stenosis after mitral valve surgery.
OBJECTIVES Transcatheter aortic valve implantation has emerged as a valuable option to treat patients with symptomatic severe aortic stenosis, who are not being considered for surgery because of significant comorbidities. Concerns exist over treating patients who have previously undergone mitral valve surgery for possible interference between the percutaneous aortic valve and the mitral prosthe...
متن کاملProsthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis.
AIMS Prosthesis-patient mismatch (P-PM) is an important determinant of morbidity and mortality following open aortic valve replacement. The aims of this study were to report its incidence and determinants following transcatheter aortic valve implantation (TAVI) with the Corevalve bioprosthesis, which have-thus far-not been described. METHODS AND RESULTS Patients with severe calcific aortic st...