Use of fractional anisotropy for determination of the cut-off value in 11C-methionine positron emission tomography for glioma

نویسندگان

  • Manabu Kinoshita
  • Naoya Hashimoto
  • Tetsu Goto
  • Takufumi Yanagisawa
  • Yoshiko Okita
  • Naoki Kagawa
  • Haruhiko Kishima
  • Hisashi Tanaka
  • Norihiko Fujita
  • Eku Shimosegawa
  • Jun Hatazawa
  • Toshiki Yoshimine
چکیده

Multimodal imaging is one of the necessary steps in the treatment of malignant brain tumors, and use of magnetic resonance imaging (MRI) and positron emission tomography (PET) are the current gold standard technique for the morphological and biological assessment of malignant brain tumors. In addition, fractional anisotropy (FA) obtained from diffusion tensor imaging (DTI) and 11C-methionine PET are useful to determine the tumor border at the tumor and white matter interface. Although there is no question of their value, a universally accepted cut-off value to discriminate normal and abnormal tissue has not been established. In this study we attempted to calculate and determine the cut-off values in FA and 11C-methionine PET that will allow delineation of the tumor border at the tumor and white matter interface by combining these two modalities. We were able to determine individual cut-off values for 11 patients, and then found an average cut-off value in the T/N ratio of 11C-methionine PET of 1.27 and in FA of 0.26, values similar to those previously confirmed by histological study. Moreover, reconstructing images delineating the tumor border was possible combining these two imaging modalities. We propose that the combined analysis of DTI and 11C-methionine PET has the potential to improve tumor border imaging in glioma patients, providing important information for establishing neurosurgical strategies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of Brain Tumors Using Amino Acid Transport PET Imaging With 18F- Fluciclovine: A Comparison Study With L-Methyl-11C-Methionine PET Imaging

Objective(s): 18F-fluciclovine (trans-1-amino-3-[18F] fluorocyclobutanecarboxylic acid, [FACBC]) is an artificial amino acid radiotracer used for positron emission tomography (PET) studies, which is metabolically stable in vivo and has a long half-life. It has already been shown that FACBC-PET is useful for glioma imaging. However, there have been no reports evaluating the efficiency of FACBC-P...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Clinical positron emission tomography for brain tumors: comparison of fludeoxyglucose F 18 and L-methyl-11C-methionine.

PURPOSE To evaluate the differences between fludeoxyglucose F 18 (FDG) and L-methyl-11C-methionine (11C-methionine) as tracers for positron emission tomography (PET) in the evaluation of brain tumors. METHODS We analyzed 10 patients with histologically verified cerebral glioma or meningioma and 1 patient with a neuroradiologic diagnosis of low-grade glioma by using FDG, 11C-methionine, and PE...

متن کامل

Substitution of 11C-methionine PET by perfusion MRI during the follow-up of treated high-grade gliomas: preliminary results in clinical practice.

PURPOSE Our aim was to compare perfusion magnetic resonance imaging (MRI) and positron emission tomography (PET) using carbon-11 labelled methionine (MET) in gliomas and their value in differentiating tumour recurrence from necrosis. MATERIALS AND METHODS We retrospectively reviewed 28 patients with a high-grade glioma. A total of 33MR perfusions and MET-PET were ultimately analysable for com...

متن کامل

Diagnostic and Prognostic Value of 11C-Methionine PET for Nonenhancing Gliomas.

BACKGROUND AND PURPOSE Noninvasive radiologic evaluation of glioma can facilitate correct diagnosis and detection of malignant transformation. Although positron-emission tomography is considered valuable in the care of patients with gliomas, (18)F-fluorodeoxyglucose and (11)C-methionine have reportedly shown ambiguous results in terms of grading and prognostication. The present study compared t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 45 2  شماره 

صفحات  -

تاریخ انتشار 2009