Tinnitus Suppression by Intracochlear Electrical Stimulation in Single Sided Deafness – A Prospective Clinical Trial: Follow-Up

نویسندگان

  • Remo A. G. J. Arts
  • Erwin L. J. George
  • Miranda Janssen
  • Andreas Griessner
  • Clemens Zierhofer
  • Robert J. Stokroos
چکیده

INTRODUCTION Earlier studies show that a Cochlear Implant (CI), capable of providing intracochlear electrical stimulation independent of environmental sounds, appears to suppress tinnitus at least for minutes. The current main objective is to compare the long-term suppressive effects of looped (i.e. repeated) electrical stimulation (without environmental sound perception) with the standard stimulation pattern of a CI (with environmental sound perception). This could open new possibilities for the development of a "Tinnitus Implant" (TI), an intracochlear pulse generator for the suppression of tinnitus. MATERIALS AND METHODS Ten patients with single sided deafness suffering from unilateral tinnitus in the deaf ear are fitted with a CI (MED-EL Corporation, Innsbruck, Austria). Stimulation patterns are optimized for each individual patient, after which they are compared using a randomized crossover design, with a follow-up of six months, followed by a 3 month period using the modality of patient's choice. RESULTS Results show that tinnitus can be suppressed with intracochlear electrical stimulation independent of environmental sounds, even long term. No significant difference in tinnitus suppression was found between the standard clinical CI and the TI. CONCLUSION It can be concluded that coding of environmental sounds is no requirement for tinnitus suppression with intracochlear electrical stimulation. It is therefore plausible that tinnitus suppression by CI is not solely caused by an attention shift from the tinnitus to environmental sounds. Both the standard clinical CI and the experimental TI are potential treatment options for tinnitus. These findings offer perspectives for a successful clinical application of the TI, possibly even in patients with significant residual hearing. TRIAL REGISTRATION TrialRegister.nl NTR3374.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DESIGN AND STRUCTURE OF A NEW DEVICE FOR AUDITORY ELECTRICAL STIMULATION FOR SUPPRESSION OF TINNITUS

Auditory Electrical Stimulation for Tinnitus Suppression Tinnitus is the conscious experience of sound which arises in the head of its owner, but without a voluntary origin obvious to that person. About 10-15% of all adults report prolonged spontaneous tinnitus (PST). There are a lot of methods for suppressing this complaint. One of these methods is electrical stimulation. Electrical stimu...

متن کامل

CINGLE-trial: cochlear implantation for siNGLE-sided deafness, a randomised controlled trial and economic evaluation

BACKGROUND Individuals with single-sided deafness (SSD) have problems with speech perception in noise, localisation of sounds and with communication and social interaction in their daily life. Current treatment modalities (Contralateral Routing of Sound systems [CROS] and Bone Conduction Devices [BCD]) do not restore binaural hearing. Based on low level of evidence studies, CROS and BCD do not ...

متن کامل

Comparison of pseudobinaural hearing to real binaural hearing rehabilitation after cochlear implantation in patients with unilateral deafness and tinnitus.

OBJECTIVE Up to now, treatment modalities of unilateral deafness consist of no treatment, conventional contralateral routing of signal (CROS), or Bone-Anchored Hearing Aid (BAHA) hearing aid. Cochlear implantation makes a new treatment modality available for patients with single-sided deafness. The aim of this study is to evaluate the use of unilateral electrical stimulation with normal hearing...

متن کامل

Curing tinnitus with a Cochlear Implant in a patient with unilateral sudden deafness: a case report

Cochlear implantation is a routine procedure for patients with bilateral profound sensorineural hearing loss. Some reports demonstrated a suppression of tinnitus as a side-effect after implantation. We describe the case of a 55-year-old man suffering from severe right-sided tinnitus in consequence of sudden right-sided deafness. Multiple therapeutic efforts including intravenous steroids and ty...

متن کامل

Spatial Selectivity to Intracochlear Electrical Stimulation in the Inferior Colliculus is Degraded Following Long-Term Deafness in Cats

In an animal model of electrical hearing in prelingually deaf adults this study examined the effects of deafness duration on response thresholds and spatial selectivity (i.e., cochleotopic organization, spatial tuning and dynamic range) in the central auditory system to intracochlear electrical stimulation. Electrically evoked auditory brainstem response (EABR) thresholds and neural response th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -