Rapid-scan EPR imaging.

نویسندگان

  • Sandra S Eaton
  • Yilin Shi
  • Lukas Woodcock
  • Laura A Buchanan
  • Joseph McPeak
  • Richard W Quine
  • George A Rinard
  • Boris Epel
  • Howard J Halpern
  • Gareth R Eaton
چکیده

In rapid-scan EPR the magnetic field or frequency is repeatedly scanned through the spectrum at rates that are much faster than in conventional continuous wave EPR. The signal is directly-detected with a mixer at the source frequency. Rapid-scan EPR is particularly advantageous when the scan rate through resonance is fast relative to electron spin relaxation rates. In such scans, there may be oscillations on the trailing edge of the spectrum. These oscillations can be removed by mathematical deconvolution to recover the slow-scan absorption spectrum. In cases of inhomogeneous broadening, the oscillations may interfere destructively to the extent that they are not visible. The deconvolution can be used even when it is not required, so spectra can be obtained in which some portions of the spectrum are in the rapid-scan regime and some are not. The technology developed for rapid-scan EPR can be applied generally so long as spectra are obtained in the linear response region. The detection of the full spectrum in each scan, the ability to use higher microwave power without saturation, and the noise filtering inherent in coherent averaging results in substantial improvement in signal-to-noise relative to conventional continuous wave spectroscopy, which is particularly advantageous for low-frequency EPR imaging. This overview describes the principles of rapid-scan EPR and the hardware used to generate the spectra. Examples are provided of its application to imaging of nitroxide radicals, diradicals, and spin-trapped radicals at a Larmor frequency of ca. 250MHz.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new strategy for fast radiofrequency CW EPR imaging: direct detection with rapid scan and rotating gradients.

Rapid field scan on the order of T/s using high frequency sinusoidal or triangular sweep fields superimposed on the main Zeeman field, was used for direct detection of signals without low-frequency field modulation. Simultaneous application of space-encoding rotating field gradients have been employed to perform fast CW EPR imaging using direct detection that could, in principle, approach the s...

متن کامل

Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude.

X-band rapid-scan EPR was implemented on a commercially available Bruker ELEXSYS E580 spectrometer. Room temperature rapid-scan and continuous-wave EPR spectra were recorded for amorphous silicon powder samples. By comparing the resulting signal intensities the feasibility of performing quantitative rapid-scan EPR is demonstrated. For different hydrogenated amorphous silicon samples, rapid-scan...

متن کامل

Detection of Blood-brain barrier disruption in a mouse model of transient cerebral ischemia by EPR imaging

INTRODUCTION EPR imaging using nitroxides is a powerful non-invasive method for visualizing the redox status modulated by oxidative stress in vivo. Recently we successfully reduced the scan time of three-dimensional (3D) EPR imaging of nitroxides in rodents. This system enables us to obtain 3D images of nitroxide probes with a half-life of a few minutes in living mice [1]. Another advantage of ...

متن کامل

Rapid Imaging of Free Radicals In Viva using Snapshot Field-Cycled PEDRI

Introduction Proton electron double resonance imaging (PEDRI) is a wellestablished method for imaging free radicals in biological samples and small animals [ 11. The EPR resonance of the free radical under study is irradiated during the acquisition of an MR image; the image intensity in parts of the sample containing free radical is altered by the Overhauser effect. In order to reduce the EPR i...

متن کامل

Rapid-scan EPR of immobilized nitroxides.

X-band electron paramagnetic resonance spectra of immobilized nitroxides were obtained by rapid scan at 293 K. Scan widths were 155 G with 13.4 kHz scan frequency for (14)N-perdeuterated tempone and for T4 lysozyme doubly spin labeled with an iodoacetamide spirocyclohexyl nitroxide and 100 G with 20.9 kHz scan frequency for (15)N-perdeuterated tempone. These wide scans were made possible by mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 280  شماره 

صفحات  -

تاریخ انتشار 2017