Effect of saturable response to two-photon absorption on the readout signal level of three-dimensional bit optical data storage in a photochromic polymer

نویسندگان

  • Min Gu
  • Jose Omar Amistoso
  • Akiko Toriumi
  • Masahiro Irie
  • Satoshi Kawata
چکیده

We observe a saturable change in the refractive index induced by two-photon absorption in a photochromic polymer, while the erasable nature of the polymer is maintained. As a result, the support region of spatial frequencies of the recorded data bits caused by the refractive index change in the polymer is enlarged. This feature leads to the significant enhancement of the signal level in a reflection confocal microscope readout system for three-dimensional photochromic bit optical data storage. © 2001 American Institute of Physics. @DOI: 10.1063/1.1383999#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photochromic diarylethene for two-photon 3D optical storage

We had accomplished recording and readout of bit patterns by two-photon 3D optical storage technology using a new photochromic diarylethene, 1,2-bis(2-methyl-5-methylene-n-butylamido-thien-3-yl) perfluorocyclopentene (BMMBTP), as memory medium. The photochromic reaction, both in solution and in poly(methyl methacrylate) (PMMA) amorphous film, and fluorescence property of BMMBTP were investigate...

متن کامل

Two-Photon Absorbing Molecules as Potential Materials for 3D Optical Memory

In this review, recent advances in two-photon absorbing photochromic molecules, as potential materials for 3D optical memory, are presented. The investigations introduced in this review indicate that 3D data storage processing at the molecular level is possible. As 3D memory using two-photon absorption allows advantages over existing systems, the use of two-photon absorbing photochromic molecul...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

Small field size dose-profile measurements: A comparison between Eclipse™ treatment planning system with NIPAM polymer gel dosimeter dose measurement

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...

متن کامل

Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter

Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001