A new method for predicting CT lung nodule volume measurement performance
نویسندگان
چکیده
Purpose: To evaluate a new approach for predicting nodule volume measurement bias and variability when scanning with a specific CT scanner and acquisition protocol. Methods: A GE LightSpeed VCT scanner was used to scan 3 new rolls of 3M 3/4 x 1000 Inch Scotch Magic tape with a routine chest protocol (120 kVp, 100 mA, 0.4 s rotation, .98 pitch, STANDARD kernel) at three different slice thicknesses and spacings. Each tape scan was independently analyzed by fully automated image quality assessment software, producing fundamental image quality characteristics and simulated lung nodule volume measurements for a range of sphere diameters. The same VCT scanner and protocol was then used to obtain 10 repeat CT scans of an anthropomorphic chest phantom containing multiple Teflon spheres embedded in foam (diameters = 4.76mm, 6.25mm, and 7.94mm). The observed volume of the spheres in the 30 (3 reconstructions per scan) repeat scans was provided by independently developed nodule measurement software. Results: The predicted vs observed mean volume (mm) and CV for 3 slice thicknesses and sphere sizes was obtained. For 0.625mm slice thickness scans the predicted vs observed values were (44.3,0.91)-vs-(48.2,1.17), (110.4,0.51)-vs-(124.1,0.47), and (219.9,0.29)-vs-(250.1,0.34), for 4.76mm, 6.25mm, and 7.94mm spheres respectively. For 1.25mm slice thickness the corresponding values were (42.1,0.98)-vs-(47.6,1.35), (106.9,0.56)-vs-(123.1,0.61), and (214.8,0.32)-vs-(248.8,0.41). For 2.5mm slice thickness the corresponding values were (23.9,9.53)-vs-(36.8,12.50), (77.6,3.84)-vs-(110.5,3.20), and (173.0,1.57)-vs-(233.9,1.32). Conclusion: Volume measurement bias and variability for lung nodules based on nodule size and acquisition protocol can potentially be predicted using a new method that utilizes fundamental image characteristics and simulation.
منابع مشابه
Volumetric Measurements of Lung Nodules with Multi-Detector Row CT: Effect of Changes in Lung Volume
OBJECTIVE To evaluate how changes in lung volume affect volumetric measurements of lung nodules using a multi-detector row CT. MATERIALS AND METHODS Ten subjects with asthma or chronic bronchitis who had one or more lung nodules were included. For each subject, two sets of CT images were obtained at inspiration and at expiration. A total of 33 nodules (23 nodules > or =3 mm) were identified a...
متن کاملطراحی سیستم کمک تشخیص کامپیوتری نوین به منظور شناسایی ندولهای ریوی در تصاویر سیتی اسکن
Background: Lung diseases and lung cancer are among the most dangerous diseases with high mortality in both men and women. Lung nodules are abnormal pulmonary masses and are among major lung symptoms. A Computer Aided Diagnosis (CAD) system may play an important role in accurate and early detection of lung nodules. This article presents a new CAD system for lung nodule detection from chest comp...
متن کاملA New Computer-Aided Detection System for Pulmonary Nodule in CT Scan Images of Cancerous Patients
Introduction: In the lung cancers, a computer-aided detection system that is capable of detecting very small glands in high volume of CT images is very useful.This study provided a novelsystem for detection of pulmonary nodules in CT image. Methods: In a case-control study, CT scans of the chest of 20 patients referred to Yazd Social Security Hospital were examined. In the two-dimensional and ...
متن کاملAutomated approach to measure pulmonary nodule volume based on radius and CT number
Determining the change in the pulmonary nodule size is a critical measurement for cancer diagnosis and therapy evaluation. In this study, an image-processing method that quantifies the nodule volume change based on computed tomography (CT) images is proposed. The proposed method consists of the following four steps: CT image interpolation, pulmonary region segmentation, nodule extraction, and n...
متن کاملAutomated pulmonary nodule detection based on three-dimensional shape-based feature descriptor
Computer-aided detection (CAD) can help radiologists to detect pulmonary nodules at an early stage. In pulmonary nodule CAD systems, feature extraction is very important for describing the characteristics of nodule candidates. In this paper, we propose a novel three-dimensional shape-based feature descriptor to detect pulmonary nodules in CT scans. After lung volume segmentation, nodule candida...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -