Association of ventricular arrhythmias detected by implantable cardioverter defibrillator and ambient air pollutants in the St Louis, Missouri metropolitan area.

نویسندگان

  • D Q Rich
  • M H Kim
  • J R Turner
  • M A Mittleman
  • J Schwartz
  • P J Catalano
  • D W Dockery
چکیده

BACKGROUND It has previously been reported that the risk of ventricular arrhythmias is positively associated with ambient air pollution among patients with implantable cardioverter defibrillators (ICD) in Boston. AIMS To assess the association of community exposures to air pollution with ventricular arrhythmias in a cohort of ICD patients in metropolitan St Louis, Missouri. METHODS ICD detected episodes reported during clinical follow up were abstracted and reviewed by an electrophysiologist to identify ventricular arrhythmias. A total of 139 ventricular arrhythmias were identified among 56 patients. A case-crossover design was used with control periods matched on weekday and hour of the day within the same calendar month. Conditional logistic regression models were adjusted for temperature, barometric pressure, and relative humidity in the 24 hours preceding the event. RESULTS There was a significant (24%, 95% CI 7% to 44%) increase in risk of ventricular arrhythmias associated with each 5 ppb increase in mean sulphur dioxide and non-significantly increased risk (22%, 95% CI -6% to 60%; and 18%, 95% CI -7% to 50%) associated with increases in nitrogen dioxide (6 ppb) and elemental carbon (0.5 microg/m3), respectively in the 24 hours before the arrhythmia. CONCLUSIONS These results provide evidence of an association between ventricular arrhythmias and ambient air pollutants in St Louis. This is consistent with previous results from Boston, although the pollutants responsible for the increased risk are different.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Association of short-term ambient air pollution concentrations and ventricular arrhythmias.

The authors evaluated the association between ventricular arrhythmias detected by implantable cardioverter defibrillators and ambient air pollution concentrations in the hours immediately before the arrhythmia. Patients given implantable cardioverter defibrillators at the New England Medical Center in Boston, Massachusetts, between mid-1995 and 1999 who lived within 40 km of a central monitorin...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Association of Air Pollution with Increased Incidence of Ventricular Tachyarrhythmias Recorded by Implanted Cardioverter Defibrillators

Epidemiologic studies have demonstrated a consistent link between sudden cardiac deaths and particulate air pollution. We used implanted cardioverter defibrillator (ICD) records of ventricular tachyarrhythmias to assess the role of air pollution as a trigger of these potentially life-threatening events. The study cohort consisted of 203 cardiac patients with ICD devices in the Boston metropolit...

متن کامل

Main air pollutants and ventricular arrhythmias in patients with implantable cardioverter-defibrillators: A systematic review and meta-analysis

Objective Previous studies of ambient air pollutants and ventricular arrhythmias in patients with implantable cardioverter-defibrillator (ICD) have yielded mixed results, and the association between air pollution and ventricular arrhythmias in these patients remains unclear. This study aimed to assess and quantify the association between exposure to major air pollutants [CO, inhalable particles...

متن کامل

Increased Risk of Paroxysmal Atrial Fibrillation Episodes Associated with Acute Increases in Ambient Air Pollution

OBJECTIVES We reported previously that 24-hr moving average ambient air pollution concentrations were positively associated with ventricular arrhythmias detected by implantable cardioverter defibrillators (ICDs). ICDs also detect paroxysmal atrial fibrillation episodes (PAF) that result in rapid ventricular rates. In this same cohort of ICD patients, we assessed the association between ambient ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Occupational and environmental medicine

دوره 63 9  شماره 

صفحات  -

تاریخ انتشار 2006