Effects of intravenously administered indocyanine green on near-infrared cerebral oximetry and pulse oximetry readings

نویسندگان

  • Ho Young Baek
  • Hyun-jung Lee
  • Joung Min Kim
  • Soo-young Cho
  • Seongtae Jeong
  • Kyung Yeon Yoo
چکیده

BACKGROUND Intravenously administered indocyanine green (ICG) may cause misreadings of cerebral oximetry and pulse oximetry in patients undergoing carotid endarterectomy under general anesthesia. The present study determined the effects of two different doses (12.5 mg vs. 25 mg) of ICG on regional cerebral tissue oxygen saturation (SctO2) and percutaneous peripheral oxygen saturation (SpO2). METHODS Twenty-six patients receiving ICG for videoangiography were divided into two groups according to the dosage (12.5 mg and 25 mg, n = 13 in each group). Heart rate, arterial blood pressure, SctO2, and SpO2 were measured before and after an intravenous bolus administration of ICG. RESULTS Following the dye administration, no changes in heart rate or arterial blood pressure were noted in either group. SctO2 was increased in both groups; however, the magnitude of the increase was greater (21.6 ± 5.8% vs. 12.6 ± 4.1%, P < 0.0001) and more prolonged (28.4 ± 9.6 min vs. 13.8 ± 5.2 min, P < 0.0001) in the 25 mg group than in the 12.5 mg group. In contrast, SpO2 was decreased in both groups; the magnitude of the decrease was greater in the 25 mg group than in the 12.5 mg group (4.0 ± 0.8% vs. 1.6 ± 1.0%, P < 0.0001). There were no differences in the time to reach the peak SctO2 or to reach the nadir SpO2 between the two groups. CONCLUSIONS In patients given ICG for videoangiography, a 25 mg bolus results in a greater and more prolonged increase in SctO2 and a greater reduction in SpO2 than a 12.5 mg bolus, with no differences in the time to reach the peak SctO2 or to reach the nadir SpO2.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The values shown on optical technology-based patient monitors must be cautiously interpreted: intravenous dye-induced errors

dyes such as indocyanine green (ICG), indigo carmine, and methylene blue are commonly used during various surgical procedures. The intraoperative administration of intravenous dyes can result in misreadings of the actual values measured by optical technology-based patient monitors (i.e., cerebral oximeters and pulse oximeters) because they interfere with the amount of the specific infrared or r...

متن کامل

Near Infrared Spectroscopy and Lower Extremity Acute Compartment Syndrome: A Review of the Literature

Similar to pulse-oximetry, Near Infrared Spectroscopy (NIRS) uses the proportionate differential in reflection and absorption of different wavelengths of light (Beer-Lambert Law) to estimate the proportion of hemoglobin saturated with oxygen approximately 2-3 cm below the sensor. The depth of readings is based on the separation between the light source (s) and the receptor (s); the farther the ...

متن کامل

Evaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

متن کامل

Evaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

متن کامل

Does ambient light affect the accuracy of pulse oximetry?

OBJECTIVE Determine whether ambient light affects the accuracy of pulse oximetry readings. DESIGN Prospective, repeated-measures study. SETTING A photographic darkroom. SUBJECTS Forty-five faculty and students at a university, none of whom had pale skin, dark skin, or evidence of cardiopulmonary disease. Any nail polish was removed. METHODS Five light sources were individually tested: i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 68  شماره 

صفحات  -

تاریخ انتشار 2015